4. Manually Controlled Operation

4.1
setting desired operating parameters
Note:
4.1.1
s
P
et
ower
1. Press and release ShIFT.
2. Press PoWER UNITS.
3. Press UP  or DoWN  to scroll through choices.
4. Press ShIFT to exit.
4.1.2
s
d
et
isPlay to
1. Press and release ShIFT.
2. Press ToRQUE UNITS.
3. Press UP  or DoWN  until you see the desired unit of measure.
4. Press ShIFT to exit.
4.1.3
s
s
et uP
ystem
1. Press and release ShIFT.
2. Press SETUP.
3. Press ShIFT.
4. Press UP  or DoWN  until you see the desired unit of input torque.
5. Press ShIFT.
6. Press UP  or DoWN  until selection matches encoder installed on dynamometer.
(60-bit = standard)
7. Press ShIFT.
8. Use the UP  or DoWN  buttons and the Decrease/Increase Dial to adjust the
maximum power setpoint for the dynamometer in use.
9. Press ShIFT to exit.
4.1.4
s
u
P
et
P
1. Press and release ShIFT.
2. Press SETUP.
3. Press the DoWN  button once.
4. Press ShIFT.
5. Press UP  or DoWN  to turn oN or oFF Torque PASS/FAIL testing.
6. If oN, press ShIFT.
7. Use the  or DoWN  buttons and the Decrease/Increase Dial to adjust the high limit
for Torque.
8. Press ShIFT.
9. Use the  or DoWN  buttons and the Decrease/Increase Dial to adjust the low limit for
Torque.
See Appendix b: Front Panel/Display Menu Flow Charts.
d
d
u
isPlay to
esired
nits
d
t
u
esired
orque
nits
P
arameters
/F
P
ass
ail
arameters
(w
, H
a
.)
atts
P or
ux
11