GB
INSTALLATION AND INSTRUCTION MANUAL
ELECTRON 450, ELECTRON 600,
ELECTRON 800, ELECTRON 900
1. ONE ELECTRIC SAUNA STOVE PACKAGE COMPRISES:
1. Stove with control equipment
2. Fixing plate + fixing screws
3. Sensing element
4. Control unit + stand
5. Sauna stove installation and instruction manual
2. PRIOR TO INSTALLATION
Perform the following checks:
- The stove is the right size (kW) for the size of the sauna (m
- Table 1 shows the sauna volumes for different stove types.
2
- For every 1 m
of uninsulated brick, tile or glass wall surface in the sauna, increase
the sauna volume by 1.5 m
The sauna volumes indicated in Table 1 are both maximum and minimum values.
Table 1. Installation data for ELECTRON stove
Stove type
Wattage
Volume
min max
kW
m
ELECTRON 450
4,5
4
ELECTRON 600
6
6
ELECTRON 800
8
8
ELECTRON 900
9
8
- Table 1 indicates both the minimum height of the sauna and the minimum safety
distances for the stove.
- Make sure the fixing plate is screwed to a solid base. Wall panelling is not solid
enough, and needs to be reinforced with either additional studs under the panel or
reinforcing boards fixed to the wall studs on top of the panel.
- The stove can also be installed in a wall recess, cf. Fig. 1.
ONLY ONE ELECTRIC STOVE TO BE INSTALLED IN A SAUNA.
3
when choosing the required stove wattage from Table 1.
Sauna
Minimum safety distances for stove
Height
Sides
Front
min
A **)
B **)
3
m
3
cm
cm
cm
7
190
5
5
9
190
5
8
13
190
10
10
15
190
10
10
Front From ceiling From floor
C **)
D **)
E **)
cm
cm
cm
2
120
5
2
120
5
2
120
5
2
120
5
**) See Fig. 1
*) Use a rubber sheathed connection cable
of type H07RN-F or corresponding
3
).
Amount of
Connection*)
stones
400V 3N
Fuses
kg
mm
2
A
30
5x1,5
3x10
30
5x1,5
3x10
30
5x2,5
3x16
30
5x2,5
3x16