Position of the hook and needle
Fig. 34: Setting the hook clearance
1. Machine locked in place at position 1 ( p. 21).
2. Loosen the screws (4) for the hook support (3).
3. Loosen the setscrews (2) for the hook clamping ring (1).
4. Move the hook support (3) sideways such that the distance between
5. Tighten the screws (4) for the hook support (3).
6. Check the loop stroke position ( p. 52).
7. Tighten the setscrews (2) for the hook clamping ring (1).
8. Remove the lock (
Order
Then check the following setting:
• Position of the needle guard ( p. 54)
Service Instructions 867 - 03.0 - 10/2017
(1) - Clamping ring
(2) - Setscrews
(3) - Hook support
the hook tip (6) and the groove for the needle (5) is 0.1 mm at most,
without the hook tip (6) touching the needle.
(4) - Screws
(5) - Needle groove
(6) - Hook tip
p. 21).