Error log information

The Hitachi Gigabit Fibre Channel Adapter provides the functions to gather the failure
information (error log) when the various failures occurred.

Linux

Linux driver collects the various error log information using the daemon process (klogd)
which outputs the kernel messages. Accordingly, klogd and syslogd must be executed to
collect log information.
Though the output destination of log information is usually /var/log/messages, the output
destination can be changed depending on the klogd and syslogd settings. Confirm these
settings in advance.
All SLES's driver supports the script 'hfcrasinfo'. By executing the hfcrasinfo command,
you can collect syslog and other driver information at the same time.

Log level

The following table shows the log levels that the Hitachi Gigabit Fibre Channel
Adapter use.
A log level value of KERN_INFO(6) or higher should be used.
Log level
KERN_ERR(3)
KERN_WARNING(4)
KERN_INFO(6)
To confirm the present log level, execute the following command.
# cat /proc/sys/kernel/printk
Message content
Message when Adapter detects error
Message when the error at the level without
the problem in operation is detected
Message to inform of output and configuration
change of Adapter information