Download Print this page

Monogram ZET2PMSS Installation Instructions Manual page 4

Advertisement

Installation Instructions
Cutout for Single Built-In Oven
A3
Under Counter
Gas or electric cooktops may
be installed over this oven.
See cooktop installation
instructions for cutout size.
See label on top of oven for
approved cooktop models.
25"
(63.5 cm)
Top and/or side fillers
may be necessary
if unit is positioned
between existing
cabinets. Be sure
they are attached
securely, since they
will anchor the oven
in the cabinet.
3/4" (1.9 cm)
Support Platform
Required
Side by Side Installations
Install two wall ovens in separate cutouts.
Allow 2" (5.1 cm) min. between cutouts.
2" (5.1 cm)
Cutout –
Min.
Observe all
dimensions
dimensions
and
requirements.
requirements.
28 1/2"
(72.4 cm) Min.
28 5/8"
(72.6 cm) Max.
27 1/4"
(69.2 cm) Min.
27 5/16"
(69.4 cm) Max.
MUST SUPPORT 200 LBS.
(90 KG)
Cutout –
Observe all
and
240V / 208V
Junction Box
Location (junction
box may be in
adjacent cabinet)
7 3/4"
(19.7 cm)
Max.
Allow 1" (2.5 cm)
overlap top of
oven and
11/16" (1.8 cm)
overlap side
edges of
cutout
Must
match
toekick
height
NOTE: This oven is only approved to be
installed under the specific models as
labeled on this unit.
6
Gas and electrical connections for
30" (76.2 cm) gas cooktop must be
located in an adjacent accessible
location to the right. For 36" (91.4 cm)
gas cooktop, the connections may be
made to the left.
36" (91.4 cm)
22" (55.9 cm)
Typical
Min. Above
Countertop
Support
Height
Platform
24"
(61 cm)
4" (10.2 cm)
Typical
Toekick

Advertisement

loading