Motor Brushes

Replace brushes worn to less than 1/2
in. (13 mm). Brushes wear differently
on each side of motor; check both
sides. Brush Repair Kit 248186 is
available; kit includes instruction sheet
406582.
Motor commutator should be smooth.
If not, resurface commutator or replace
motor.
1. See Before Beginning Repair, page 35.
Relieve pressure, page 22.
2. See instruction sheet 406582, included
with Brush Repair Kit 248186. Remove old
brushes and install new ones supplied in
kit.

Fan

1. Disconnect fan cable (75) from fan (202).
With Motor Power on, test cable connector
for line voltage (120 V).
2. If voltage is correct, fan is defective.
Remove screws holding fan to shield (206).
Install new fan in reverse order.
3. If voltage is not correct, check fan cable
connection at J9 on control board; see F
12, page 43.
313221A
F
. 18. Fan
IG
.
IG
Repair
202
75
TI7030a