Slot Card Specifications and Connection Information
PCTFI card
Table A-17 describes the PCTFI slot card status lights.
Table A-17. PCTFI card status lights
Lights
Fault
Fault
Active PCTI
OOS
Active PCTI
OOS

Connecting the PCTFI slot card to the switch

The time-slot interchange unit of the 5ESS switch uses two BKD10 boards, installed as a
time-slot interchange slice (TSIS) board pair. One BKD10 board is inserted into TSIS side 0.
The other BKD10 board is inserted into TSIS side 1.
The PCTFI card connects to the BKD10 board-pair with a pair of 62.5 micron (µm) fibers with
MT-RJ connectors at both ends. Each fiber must not exceed 2000 feet (610 meters).
Each peripheral control and timing (PCT) facility interface link is a duplexed connection, with
one active and one standby link. The 5ESS switch determines which side of the duplex PCT
facility interface is selected for data transmission.
A-22
Color
Description
Red
On when there is a failure of the 3.3V power supply.
Yellow
On when the card is in reset or fault condition.
Yellow
On if the link for either PCT side 0 or PCT side 1 is
unavailable or out of service (OOS).
Green
On if the link for either PCT side 0 or PCT side 1 is active or
standing by.
MAX TNT Hardware Installation Guide