Wiring examples

1. Light without neutral conductor
3. Connection using series switch for
manual and automatic operation
1) e.g. 1-4 x 100 W filament bulbs
2) Service load, light of 1000 W max. (see Technical specifications)
3) IS 2180/2 connection terminals
4) Indoor switch
5) Indoor series switch, manual, automatic
6) Indoor double-throw switch, automatic, permanent light ON
Operation/Maintenance
The Infrared Sensor is
suitable for switching light
on and off automatically.
The unit is not suitable for
special burglary alarm
systems since it lacks the
tampering protection
prescribed for this purpose.
18
2. Light with neutral conductor
4. Connection to double-throw switch
for permanent light ON and automatic
operation
Setting I: automatic operation
Setting II: manual operation for permanent
light ON
Important: the unit cannot be switched off,
but operated only at settings I and II.
Weather conditions may
affect the way the motion
detector works. Strong
gusts of wind, snow, rain or
hail may cause the light to
come on when it is not
wanted because the sensor
is unable to distinguish
sudden changes of tem-
perature from sources of
heat. The detector lens
may be cleaned with a
damp cloth it it gets dirty
(do not use cleaning
agents).