Download Print this page

Huawei RTN 360 V100 Quick Installation Manual page 9

Hide thumbs Also See for RTN 360 V100:

Advertisement

References for Installation
Aligning an RTN 360
Install the alignment scope.
Adjust the azimuth and elevation of the local RTN 360 slowly to
move the crosshair of the alignment scope to the peer RTN 360.
Peer site
16/17 >>
Eyepiece
Lens
Holes for installing
the alignment scope
Tighten the azimuth and elevation adjustment nuts.
Align the peer RTN 360 with the local RTN 360 in the
same way.
Remove the alignment scope.
Adjust the azimuth and elevation of the RTN 360 by rotating the azimuth and
elevation adjustment nuts.
.
By rotating azimuth
adjustment nut (nut 1),
1
you can adjust the
azimuth of the RTN
360 from -50° to
+50°.
By rotating the elevation adjustment nut (nut
2), you can adjust the elevation of the RTN
360 from -50° to +50°.
To adjust the azimuth and elevation of an RTN 360, rotate the
azimuth and elevation adjustment nuts. Do not attempt to turn
the device or mounting kits.
If the azimuth adjustment is insufficient to align the RTN 360
with its peer, loosen the hose clamp, re-position the RTN 360,
and then fasten the hose clamp.
2

Advertisement

loading