PowerDsine PD-6548 User Manual

Power over ethernet midspans 48-port model ieee 802.3af-compliant

Advertisement

Quick Links

P
o
w
e
r
P
o
w
e
r
M
M
4
8
4
8
I
E
E
E
8
0
I
E
E
E
8
0
U
U
o
v
e
r
E
t
o
v
e
r
E
t
i
d
s
p
a
n
i
d
s
p
a
n
P
D
-
6
5
4
8
P
D
-
6
5
4
8
-
P
o
r
t
M
o
d
-
P
o
r
t
M
o
d
2
.
3
a
f
-
c
o
m
2
.
3
a
f
-
c
o
m
s
e
r
G
u
i
d
e
s
e
r
G
u
i
d
e
h
e
r
n
e
t
h
e
r
n
e
t
s
s
e
l
e
l
p
l
i
a
n
t
p
l
i
a
n
t

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PD-6548 and is the answer not in the manual?

Questions and answers

Summary of Contents for PowerDsine PD-6548

  • Page 2 PD-6548 Power over Ethernet Solutions Cat. No.: 06-6860-056...
  • Page 3: All Rights Reserved

    PowerDsine Ltd. reserves the right to make changes to products and to their specifications as described in this document, at any time, without prior notice. This material may not be photocopied or reproduced without permission.
  • Page 4: Table Of Contents

    3.5 Connecting Data Cables ...22 3.6 Connecting Power Cables...22 3.7 Powering up ...22 3.8 Troubleshooting...23 3.8.1 Preliminary Steps ...23 3.8.2 Troubleshooting Guide...23 3.9 Technical Specifications...25 3.9.1 Physical Specifications...25 EMOTE ANAGEMENT Power over Ethernet Solutions Contents THERNET IDSPAN THERNET IDSPAN PD-6548 Cat. No.: 06-6860-056...
  • Page 5 PD-6548 List of Figures Figure 2-1: Power over Ethernet Midspan, Front View (PD-6548) ... 11 Figure 2-2: Connecting to the Midspan... 16 Figure 3-1: Typical Installation... 17 Figure 3-2: Cable Connections ... 20 Figure 4-1: Management Deployment ... 26 List of Tables Table 2-1: Power Status Indications ...
  • Page 6 The serial number can be found on the label at the rear of the Power over Ethernet Midspan. Electrical Compatibility Approvals The PD-6548 complies with the following standards: • FCC Part 15, Class B, with FTP cabling; Class A with UTP cabling •...
  • Page 7: Abbreviations

    PD-6548 Abbreviations PD – Powered Device SELV - Safety Extra Low Voltage DTE – Data Terminal Equipment Element Management System EMS - UTP – Unshielded Twisted Pair FTP – Foiled Twisted Pair DHCP – Dynamic Host Configuration Protocol SNMP – Simple Network Management Protocol GUI –...
  • Page 8: Safety Information

    The Power over Ethernet Midspan "Data" and "Data + Power" ports are shielded RJ-45 data sockets. They cannot be used as Plain Old Telephone Service (POTS) telephone sockets. Only RJ-45 data connectors may be connected to these sockets. Power over Ethernet Solutions Cat. No.: 06-6860-056 PD-6548...
  • Page 9: Power Cord

    Neutral, connected directly to ground The Power over Ethernet Midspan is covered by General Approval, NS/G/12345/J/100003, for indirect connection to a public telecommunications system Power over Ethernet Solutions No. 18 AWG Type SV or SJ Three-conductor. PD-6548 Cat. No.: 06-6860-056...
  • Page 10: About The Power Over Ethernet Midspan

    Midspan PowerDsine’s Midspans family, injects DC power over data-carrying Ethernet cabling. The PD-6548 Midspan, supports 48 ports in a 10/100BaseTx Ethernet network, over TIA/EIA-568 Category 5/5e/6 cabling. DC operating power, for data terminal units, is fed over the unused pairs of the cabling (7/8 and 4/5).
  • Page 11: 10/100Base-Tx Ports Definition

    PDs should not exceed 100 meters (328 ft). In accordance with the IEEE 802.3 standard, the Power over Ethernet Midspan is guaranteed to work up to this distance. Figure 2-1: Power over Ethernet Midspan, Front View Figure 2-2: Power over Ethernet Midspan, Rear View Power over Ethernet Solutions Cat. No.: 06-6860-056 PD-6548...
  • Page 12: Indicators

    Due to the standard detection process performed on each PoE port, power is not supplied to an Ethernet device that is not PoE-enabled. In this way, PDs (non PoE -enabled) are not affected by connection to Midspan’s output port. Power over Ethernet Solutions Cat. No.: 06-6860-056 PD-6548...
  • Page 13: Table 2-1: Power Status Indications

    No DC voltage is present on the spare pairs. Power to the port is not connected or, if previously connected –disconnected at the moment. No DC voltage is present on the spare pairs. PD-6548 Remarks Port Voltage Cat. No.: 06-6860-056...
  • Page 14: Connectors

    PC. Pin connections for the D-type connector are as follows: Power over Ethernet Solutions Description Plus signal, transmit from midspan Minus signal, transmit from midspan Plus signal, received to midspan Minus signal, received to midspan PD-6548 Cat. No.: 06-6860-056...
  • Page 15: Table 2-3: Console Cable D-Type Connector

    DTE transmit data DTE GND Description Plus signal, Receive from DTE to PD Minus signal, Receive from DTE to PD Plus signal, Transmit from DTE to PD Minus signal, Transmit from DTE to PD PD-6548 (Per Channel) Cat. No.: 06-6860-056...
  • Page 16: Figure 2-2: Connecting To The Midspan

    Feeding power (+) Minus signal, Transmit from DTE to PD Feeding power (-) Feeding power (-) RJ-IN RJ-OUT Data Data Data Data Midspan Channel PD-6548 Data Data Data RJ-45 DC + DC + Data DC - DC - Cat. No.: 06-6860-056...
  • Page 17: Installing The Power Over Ethernet Midspan

    Midspan to be rack mounted, as described in the next Paragraph. Figure 3-1: Typical Installation Installation process should be conducted by a qualified technician in the following way: Rack Mounting Brackets Routing the Input Ports Cables Assembling Midspan to Rack Power over Ethernet Solutions Cat. No.: 06-6860-056 PD-6548...
  • Page 18: Rack Mounting Brackets

    2. Tighten two brackets to both sides of the rack‘s rails using the supplied plates and 10-32” screws as shown below. DETAIL-A 2 PLS. RAIL CLIP NUT PLATE CLIP NUT SCREW CSK NF 10-32 (x2) Power over Ethernet Solutions BRACKET PD-6548 Cat. No.: 06-6860-056...
  • Page 19: Routing The Input Ports Cables

    Midspan cables connection may also be performed by firstly assembling the midspan to the rack by the brackets. In such a case take all necessary precautions to prevent the Midspan from falling down to the floor! Power over Ethernet Solutions Chasis ‘Ears’ Cat. No.: 06-6860-056 PD-6548...
  • Page 20: Figure 3-2: Cable Connections

    PD-6548 Figure 3-2: Cable Connections 4. Upon completion of 48 cables connections, the Midspan should be installed into the rack. Power over Ethernet Solutions Cat. No.: 06-6860-056...
  • Page 21: Assembling Midspan To Rack

    10-32” screws plus lock washer and flat washer (one on each side of the rack). Note: Verify that the Midspan’s ventilation holes on both sides are not blocked and are free of dust and foreign objects! Power over Ethernet Solutions Cat. No.: 06-6860-056 PD-6548...
  • Page 22: Connecting Data Cables

    Notes: ♦ A readily accessible disconnect device shall be incorporated in the building installation wiring. ♦ The PD-6548 Midspan should be installed at Restricted Access Location Powering up The Power over Ethernet Midspan has no on/off switch. To apply or remove power to the Midspan, insert or remove the power cable from the AC receptacle on the rear panel of the unit.
  • Page 23: Troubleshooting

    Remove and re-apply power to the device and check the indicators during power up sequence as described in Para. 3.7. cable, with four pairs. splitter. another Midspan. If it works, there is probably a faulty output port or RJ-45 connection. manaegment. PD-6548 Cat. No.: 06-6860-056...
  • Page 24 100 m or less. Try to re-connect the same end device into a different port on the same unit or into another Midspan – if it works, there is probably a faulty input/output port, or RJ-45 connection. PD-6548 Cat. No.: 06-6860-056...
  • Page 25: Technical Specifications

    Depth: 460mm, 18.1” Weight: 7.5 Kg, 15 lb. Temperature - Operating - Storage Humidity Power over Ethernet Solutions 0 to 40 °C (32 to 122 °F) -20 to 70 °C (-4 to 158 °F) 10 to 90% (non-condensing) PD-6548 Cat. No.: 06-6860-056...
  • Page 26: Remote Web Management

    Remote Web Management Remote Web Management is an optional feature, for monitoring and control of the device. For further details, refer to PowerDsine’s PowerView, Power over Ethernet Web Manager User Guide. PowerView manages Midspans via an Web Manager or via a remote Network Management station, using Java applets.
  • Page 27 PD-6548 Power over Ethernet Solutions Cat. No.: 06-6860-056...
  • Page 28 Covered under U.S patent S/N 6,473,608 and equivalent worldwide Visit our web site at: www.powerdsine.com For technical support, call: +972-9-7755123 In the USA: +631-756-4680 or 1-877-4-802-3AF Part Number: 06-6860-056 Rev 1.1...

This manual is also suitable for:

6548

Table of Contents