Power Cord - PowerDsine PD-6548 User Manual

Power over ethernet midspans 48-port model ieee 802.3af-compliant
Table of Contents

Advertisement

1.2

Power Cord

In the event that the power cord is replaced, the replacement must meet local
requirements.
For reliable connection to an AC MAINS SUPPLY, equipment provides
an appliance IEC60320 inlet for connection of a detachable power
supply cord.
The power socket outlet must be located near the Midspan and be
easily accessible. The only way to remove power from the unit is by
disconnecting the power cord from the outlet
This unit operates under SELV (Safety Extra Low Voltage) conditions
according to EN60950/IEC 950. The conditions are only maintained if
the equipment to which it is connected, also operates under SELV
conditions.
U.S.A. and
Canada
Denmark
Switzerland
France and
Peru
U.K
Power over Ethernet Solutions
The cord must be UL-approved or CSA certified.
The minimum specification for the flexible cord is:
No. 18 AWG
Type SV or SJ
Three-conductor.
The cord set must have a rated current capacity of at least
10 A.
The attachment plug must be an earth-grounding type with a
NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V)
configuration.
The supply plug must comply with section 107-2-D1,
standard DK2-1a or DK2-5a.
The supply plug must comply with SEV/ASE 1011.
This unit cannot be powered from IT supplies. If your
supplies are of the IT type, this unit must be powered by 230
V (2P+T), via an isolation transformer with a 1:1 ratio and
with the secondary connection point labeled Neutral,
connected directly to ground
The Power over Ethernet Midspan is covered by
General Approval, NS/G/12345/J/100003, for indirect
connection to a public telecommunications system
9
PD-6548
Cat. No.: 06-6860-056