PowerDsine cannot accept responsibility for inadvertent errors, inaccuracies, subsequent changes or omissions of printed material. PowerDsine Ltd. reserves the right to make changes to products and to their specifications as described in this document, at any time, without prior notice.
Data & Power Output Ports Indicators 2.3.1 Primary Power Indicator 2.3.2 Port Indications INSTALLING THE POWER OVER LAN MIDSPAN Background Information Connecting Cables Powering up Rack-Mounting Brackets Troubleshooting 3.5.1 Preliminary Steps 3.5.2 Troubleshooting Guide Power over LAN Solutions Contents PD-3006/12 Cat. No.: 06-6831-056...
Page 4
PD-3006/12 Before proceeding, record the unit’s serial number below for future reference. The serial number can be found on the information label at the rear of the Power over LAN Midspan. Serial Number Power over LAN Solutions Cat. No.: 06-6831-056...
The Power over LAN Midspan "Data" and "Data + Power" ports are shielded RJ-45 data sockets. They cannot be used as Plain Old Telephone Service (POTS) telephone sockets. Only RJ-45 data connectors may be connected to these sockets. Power over LAN Solutions Cat. No.: 06-6831-056 PD-3006/12...
* U.K. only: The Power over LAN Midspan is covered by General Approval, NS/G/12345/J/100003, for indirect connection to a public telecommunications system. Power over LAN Solutions - No. 18 AWG - Type SV or SJ - Three-conductor. PD-3006/12 Cat. No.: 06-6831-056...
About the Power over LAN Midspan PowerDsine’s family of Power over LAN Midspans, series 3000, injects power over data-carrying Ethernet cabling. The PD-3006/3012 Midspans, support 6 and 12 ports respectively in a 10/100BaseTx Ethernet network, over TIA/EIA- 568 Category 5/5e/6 cabling. The DC operating power for the data terminal units is fed over unused pairs of the cabling (7/8 and 4/5).
A Main (power) indicator on the front panel, shows the status of the Midspan. This indicator illuminates green when power is applied to the Midspan. In case of a problem with the device, the indicator illuminates in orange. Power over LAN Solutions PD-3006/12 Cat. No.: 06-6831-056...
Port Load Conditions Power to the port is disconnected. No DC voltage present on spare pairs. Continuous nominal DC voltage is present on the spare pairs. PD-3006/12 Remarks Internal power supply voltage is within tolerance. All ports are disconnected. Built-in-Test (BIT) failed.
Page 10
(constant DC ) into the port. No voltage is present on the spare pairs. Power to the port is not applied. Power management evoked. Power to the port is not applied. PD-3006/12 Port Voltage Cat. No.: 06-6831-056...
1. Connect cables from the Ethernet Switch to the Data ports (bottom row on Midspan). 2. Connect the cables from the IEEE 802.3af ready terminals (PDs) to the corresponding Data & Power ports (top row on Midspan). Power over LAN Solutions Figure 3-1: Typical Installation PD-3006/12 Cat. No.: 06-6831-056...
Ports are now enabled for normal operation. Rack-Mounting Brackets Mounting brackets are available to install the Midspan in a 19-inch rack. An optional accessory kit can be ordered as PowerDsine catalog number PD- 3000/MK. This kit consists of: * Left-hand bracket (MB-6831-011)
Page 13
PD-3006/12 Figure 3-2: Installing Brackets on Midspan Figure 3-3: Rack Mounting the Midspan Power over LAN Solutions Cat. No.: 06-6831-056...
100 and 240 Vac. the indicators during power up sequence. is not enabled. straight-wired cable, with four pairs. known-good splitter. port. same or into different Midspan. If it works, there is probably a faulty port or RJ-45 connection. PD-3006/12 Cat. No.: 06-6831-056...
-20 to 70 °C (-4 to 158 °F) 10 to 90% (non-condensing) 90 to 264 VAC at 47-63 Hz 1.5 A max. at 115 Vac 92 W max. 15.4 W (not to exceed 92 W total for all ports) 44 to 57 VDC PD-3006/12 Cat. No.: 06-6831-056...
Page 16
Visit our web site at: www.powerdsine.com For technical support, call: +972-9-7755123 In the USA: +631-756-4680 or 1-877-4-802-3AF Cat. No.: 06-6831-056 Release 1.0...