PowerDsine Ltd. reserves the right to make changes to products and to their specifications as described in this document, at any time, without prior notice. This material may not be photocopied or reproduced without permission.
ECHNICAL PECIFICATIONS 5.1 Physical Specifications... 17 5.2 Environmental Specifications ... 17 5.3 Electrical Specifications ... 17 ’ OWER SINE OWER PowerDsine Contents ...5 THERNET IDSPAN THERNET ...15 ...17 ...18 PowerDsine 6500 Series ...7 ...12 IDSPAN The Power over Ethernet Pioneers...
Page 4
Power over Ethernet Midspan. Electrical Compatibility Approvals The Powerdsine 6500 complies with the following standards: • FCC Part 15, Class B, with FTP cabling; Class A with UTP cabling • EN 55022 (CISPR 22), Class B with FTP cabling; Class A with UTP cabling •...
Power" ports are shielded RJ-45 data sockets. They cannot be used as Plain Old Telephone Service (POTS) telephone sockets. Only RJ-45 data connectors may be connected to these sockets. • Associated ethernet wiring shall be limited to inside of the building. PowerDsine The Power over Ethernet Pioneers...
Neutral, connected directly to ground The Power over Ethernet Midspan is covered by General Approval, NS/G/12345/J/100003, for indirect connection to a public telecommunications system PowerDsine No. 18 AWG Type SV or SJ Three-conductor. The Power over Ethernet Pioneers...
About the Power over Ethernet Midspan PowerDsine’s family of Power over Ethernet Midspans, series 3500 & 6500, injects power over data-carrying Ethernet cabling. The PD- 6506/6512/6524 Midspans, support 6, 12 and 24 ports respectively in a 10/100BaseTx Ethernet network, over TIA/EIA-568 Category 5/5e/6 cabling.
The Power over Ethernet Midspan is not a repeater. As such, the maximum distance from the Ethernet switch must not exceed 100 meters (328 ft). As specified in the IEEE 802.3 standard, the Power over Ethernet Midspan is guaranteed to work up to this distance.
(LED is off) to a PD. PDs that are not of the PoE-enabled type are not affected by this connection Table 2-1: Power Status Indications Indicator Color Main Green PowerDsine "Power over Ethernet Main Power Status Internal power Internal power supply supply unit is voltage is too low.
Page 10
Valid load Total aggregated power Green blinks at a exceeds pre-defined 0.5 sec. rate power budget (400w by default) PowerDsine Status Indications Port Port Voltage Power to the port is disconnected. No DC voltage present on port output lines. Continuous nominal DC voltage is...
Each data port is configured as shown in Figure 2-3, as data “Pass- Through” ports for all data pins (pins 1, 2, 3 and 6). Ensure that Category 5 or higher cabling is used, as shown in the above figure. PowerDsine Pin 3 is Transmit (TXD)
Background Information As shown in Figure 3-1, the Midspan is connected in series with an Ethernet switch/hub. The data outputs from the switch are connected to the Midspan. The Midspan delivers power over the spare twisted pairs (pins 7/8 and pins 4/5) of the Category 5 cabling, without degrading the quality of data.
Reliable Earthing — Reliable earthing of rack mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g., use of power strips) PowerDsine The Power over Ethernet Pioneers...
(1,2, 3 & 6) conductors of the RJ-45 connectors. Use Category 5 cabling when making the connections. 1. Connect cables from the Ethernet Switch to the Data In ports (lower row on the front panel). 2. Connect the cables from the IEEE 802.3af ready terminals (PDs) to the corresponding Data &...
5. Verify that the PD is connected to the Data & Power output port. 6. Try to reconnect the same PD to a different port on the same or into 7. Verify that port shutdown command was not issued via the Web PowerDsine Corrective Steps Establish that the power cord is viable.
Page 16
2. Terminals 4/5 and 7/8 are shorted together. orange? 3. Forced external power fed into the port. During these conditions, port power is disconnected. PowerDsine Corrective Steps 5 straight (non-crossover) cabling, with all four pairs. Verify that the link is 100 m or less.
5Kg (11lb) 0 to 40 °C (32 to 104 °F) -20 to 70 °C (-4 to 158 °F) 10 to 90% (non-condensing) PD-6506/6512/6524/AC/M 90 to 264 VAC at 47-63 Hz 4 A max. 200W max. 15.4 W (not to exceed Total Output Power)
PowerDsine’s PowerView Pro PowerDsine PowerView Pro is a secure remote management system offering real time monitoring and control, with graphical representation, status indicators, and alarms. PowerView Pro manages Midspans via a Internet browser interface or via a Network Management System (NMS).
Page 19
PowerDsine The Power over Ethernet Pioneers...
Page 20
Covered under US Patent 6,473,608. Other Patents pending. Visit our web site at: www.powerdsine.com For technical support, call: +972-9-7755123 In the USA: +631-756-4680 or 1-877-4-802-3AF Email: customer.care@powerdsine.com Document Number: 06-1210-056 Release 1.2...