Maintenance; Fuses; Disposal; Technical Data - Truma BG 10 Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
The water temperature cannot be preselected, automat-
ic temperature limit at approx. 70 °C. The device can be
operated with gas and electricity simultaneously in order to
speed up the heating of the boiler contents.
The electric heating element is fitted with an overtem-
perature sensor. In the event of a fault, switch off at the
control panel. Check the water content, topping up if neces-
sary (close drain valve). Wait for 10 minutes, then switch on
again.

Maintenance

We recommend the use of suitable commercially available
products to clean, sterilise and maintain the boiler. Products
containing chlorine are not suitable.
The boiler should be heated to 70 °C at regular intervals to
prevent infestation by microorganisms.
Clean the device and the ventilation slots with a dry, lint-free
cloth.

Fuses

The 12 V fuse for the boiler is on the electronic control unit on
the device.
Fig. 5
The fine fuse on the control board must always be re-
placed with a fuse of the same type: 1.6 A (slow-acting),
EN 60127-2-3.
If the electronics control board is defective, return it in
well-padded packaging. No claims may be made under the
warranty if inadequate packaging is used.
Only use original control boards as spare parts for the Truma
Boiler!

Disposal

The device must be disposed of in accordance with the ad-
ministrative regulations of the respective country in which it is
used. National regulations and laws (in Germany, for example,
the End-of-Life Vehicle Directive) must be observed.

Technical data

determined in accordance with EN 15033 or Truma test
conditions
Manufacturer
Truma Gerätetechnik GmbH & Co. KG
Postfach 1252
85637 Putzbrunn (Munich)
Germany
Water capacity
10 litres
Pump pressure
max. 2.8 bar
System pressure
max. 4.5 bar
Gas type
Liquid gas (propane/butane)
Operating pressure
30 mbar
Rated thermal output
1500 W
Gas consumption
120 g/h
Heating time from approx. 15 °C to approx. 70 °C
Gas mode:
Electrical mode:
Gas and electrical mode:
Power consumption at 12 V
Ignition:
0.17 A
Heating:
0.08 A
Standby:
0.04 A
Power consumption at 230 V (BGE 10)
Heating: (3.7 A) 850 W / (5.7 A) 1300 W
Standby – gas consumption
approx. 70 W
Weight without water
(BG 10)
approx. 6.7 kg
(BGE 10)
7.2 kg
Subject to technical changes.
1.6 A
Dimensions
All dimensions in mm.
129
Fig. 6
approx. 31 min.
approx. 29 min. (BGE 10)
approx. 16 min. (BGE 10)
30
132
383
347
Water
connection
Cowl
Electronics
Gas connection
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bge 10