When I turn de boiler BG10 on I hear ik ticking to spark de gas as it should but then the light comes up after a few seconds. I kept trying but the light keep coming on?
1 comments:
Mr. Anderson
April 12, 2025
If the light (red LED) keeps coming on after attempting to ignite the Truma BG 10 boiler, it indicates a fault. Possible causes include:
– No 12 V power supply: Check the battery voltage (must be at least 10.5 V) and the boiler fuse. – Window above the cowl is open: Close the window. – Cowl cover is fitted or soiled: Remove the cover and clean if needed. – No gas supply or incorrect gas pressure: Check the gas valves and cylinder. – Air in the gas supply: Turn off the device, wait 5 minutes, then turn it on again.
These issues prevent the boiler from operating correctly and trigger the fault light.
– Installation in trailers and vehicles used to transport hazard- Preparation ................5 ous goods is prohibited Filling the Truma Boiler with water ........5 Starting up – gas mode ............. 5 – Heating of liquids other than drinking water (e.g. cleaning, Start-up –...
Page 3
In order to prevent any hazards caused What must I do if I smell gas? by unintentional resetting of the over- temperature sensor, the appliance must not be – Avoid ignition sources, e.g. extinguish all supplied with power via an external switching naked flames, do not actuate any electrical device such as a time switch, or connected to switches or use any mobile phones or radios...
The not been used. Truma MonoControl CS gas pressure regulation system fulfils this requirement. Alternatively, two hot water-resistant shut-off National regulations and rules must be followed.
Draining the boiler If the caravan is not being used during the frosty peri- od, the Truma Boiler must be drained! Switch off the power for the water pump (main switch or pump switch). 1,6 A Turn on the hot water taps in the bathroom and kitchen.
Technical data Dimensions determined in accordance with EN 15033 or Truma test conditions Manufacturer Truma Gerätetechnik GmbH & Co. KG Postfach 1252 85637 Putzbrunn (Munich) Germany Protection class IP21 Water capacity Gas connector 10 litres Pump pressure max. 2.8 bar System pressure max.
Warm water coming out of cold – Hot water flowing – Fit a non-return valve to the cold water supply water tap. back into cold water (see installation instructions, “Water connection”). supply. If these actions do not remedy the problem, please contact Truma Service.
The warranty must be claimed with an authorised service part- sumer. The Manufacturer or an authorised service partner ner or at the Truma Service Centre. All the relevant addresses undertakes to remedy such defects through subsequent fulfil- and phone numbers can be found at www.truma.com, in the ment, i.e.
Page 10
Should problems occur, please contact the Truma Service Centre or one of our authorised service partners (see www.truma.com). In order to avoid delays, please have the unit model and serial number ready (see type plate). Truma Gerätetechnik GmbH & Co. KG Service Wernher-von-Braun-Straße 12...
Need help?
Do you have a question about the BG 10 and is the answer not in the manual?
Questions and answers
When I turn de boiler BG10 on I hear ik ticking to spark de gas as it should but then the light comes up after a few seconds. I kept trying but the light keep coming on?
If the light (red LED) keeps coming on after attempting to ignite the Truma BG 10 boiler, it indicates a fault. Possible causes include:
– No 12 V power supply: Check the battery voltage (must be at least 10.5 V) and the boiler fuse.
– Window above the cowl is open: Close the window.
– Cowl cover is fitted or soiled: Remove the cover and clean if needed.
– No gas supply or incorrect gas pressure: Check the gas valves and cylinder.
– Air in the gas supply: Turn off the device, wait 5 minutes, then turn it on again.
These issues prevent the boiler from operating correctly and trigger the fault light.
This answer is automatically generated