  • Page 1 Spectra Frameless & Spectra Nostalgic Installation Guide...
  • Page 2: Table Of Contents

    Content Introduction ..................1 Safety and general information ..............2 Installation requirements ................. 3 Builders opening and surround ............. 3 Dimensions of the appliance ............... 4 Flue requirements................8 Determining of the right flue restrictor ............10 Instruction for Installation ............... 12 Gas Connection ................
  • Page 3: Introduction

    1 Introduction Note: these instructions should be read carefully and retained for future reference. Please leave these instructions with the user. There are two models of the Spectra Frameless: • Spectra Frameless with steelplated interior • Spectra Frameless Nostalgic with bricklining This manual covers both models.
  • Page 4: Safety And General Information

    2 Safety and general information Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible. This gas appliance is factory set and can not be adjusted. This appliance does not contain any component manufactured from asbestos or any asbestos related products.
  • Page 5: Installation Requirements

    • always ventilate the space above the appliance. Use a Faber ventilation grid • to avoid cracking, the plaster has to dry for at least 1 day per millimetre plaster •...
  • Page 6: Dimensions Of The Appliance

    Dimensions of the appliance Builders opening Wirdum surround Jellum surround No surround (mm) A Opening width 1070 1070 1070 B Opening height 1050 1050 1050 C Opening depth D Min. Height shelf N.a. N.a. from top opening E Shelf depth N.a.
  • Page 7 3.2.1 Appliance with Wirdum surround Wall Surround Close builders opening with promatect < < < <...
  • Page 8 3.2.2 appliance with Jellum surround Wall Surround > > > >...
  • Page 9 3.2.3 Appliance without surround Close builders opening using promatect Window opening Threshold < < < <...
  • Page 10: Flue Requirements

    The appliance is of the type C11/C31. The appliance will need to be supplied with the approved Faber flue pipes and terminal, it is not possible to supply your own. The minimum effective height of the flue system must be 0,5 or 1 meter, depending on the appliance.
  • Page 11 Example calculation 1: Calculating horizontal extension fig. 2a: Flue lenght C + E = 1m + 1m Elbows D = 2m Total horizontal extension Measure or calculate effective height (Hvert) Flue lenght A Roof mounted terinal Total effective height When calculating table 2: It is allowed. Remove the flue restrictor! Example calculation 2: Calculation horizontal extension fig.
  • Page 12: Determining Of The Right Flue Restrictor

    Determining of the right flue restrictor Horizontal extension (m) Spectra Frameless Calculate the total horizontal- and vertical length of the flue, according to the calculations displayed above. Determine according to the table the right flue restrictor size. When meeting an X, and when the values are outside the table, the combination is not allowed.
  • Page 13 The existing chimney needs to have an opening of min. 150 x 150 mm. The chimney needs to be intact and well looked after. Use the Faber adjustable roof-mounted-terminal especially made for this purpose, and the chimney connection set. The min. distance between two terminals should be at least 450 mm.
  • Page 14: Instruction For Installation

    4 Instruction for Installation Gas Connection Installation pipes should be in accordance with BS 6891. Pipe work from the meter to the appliance must be of adequate size. The complete installation including the meter must be tested for soundness and purged as described in the above code.
  • Page 15: False Chimney Brest Without Surround

    False chimney Brest without surround Remove the knock-outs in the DC-box and place vertically the metal studs in the knock-outs Build the false chimney using Promatect The measure in the clear of the false chimney Brest has to be 840x830 (width x height).
  • Page 16: Removal Of The Glass

    Removal of the glass Two suction pads are delivered with the appliance to make removal easier. Fig. 4.4: Suction pad open Fig. 4.5: Suction pad closed Fig. 4.6: Suction pad in use Always clean the suction lifters before use Place the suction lifters at the glass Remove the glass-clamp at the bottom side after removing the knurled screws (see figure 10) Place the suction lifters on the glass and bring the handles towards each other...
  • Page 17: Placing The Log Set

    Place the log set as shown in the figures 4.10 till 4.12 Optionally the embers can be dispersed over the stoke hole. Be careful not to cover the mesh at the backside. Note: The two logs at the back (see figure 4.12) of the Spectra Frameless Nostalgic don’t have to be Fig.
  • Page 18: Installation Of The Flue

    5 Installation of the flue Connection with use of concentric duct material Make a hole of ø 153 mm for the wall or roof mounted terminal The horizontal pipes need to rise at an angle from the appliance at the rate of 3 degrees per metre Build the system starting from the appliance Make sure you place the pipes in the right direction, the narrow end towards the...
  • Page 19 1. Place the aluminium closure plate (A) onto the chimney. Permanently attach and make airtight. 2. Pull the liner (C) through the chimney. 3. Connect the liner onto the roof terminal and fix this with the clamp provided with the chimney connection set.
  • Page 20: Commissioning (Functional Checks)

    6 Commissioning (functional checks) Pilot ignition check • Ignite the pilot light as described in the user manual. • Check if the pilot burner stays alight. • Extinguish the pilot burner. Check functional burner and pilot burner The appliance is preset to give the correct heat input. No further adjustment is necessary. Always check the inlet pressure and burner pressure: •...
  • Page 21: Handing Over (Final Check And Customer Briefing)

    7 Handing over (final check and customer briefing) Instruct the customer on the full operation of the appliance and the remote control, including replacement of batteries Advise the customer how to clean the appliance including the glass Hand over these instructions including the user guide to the consumer Recommend that the appliance should be serviced by a competent person at least once a year 8 Servicing...
  • Page 22 Burner tray assembly Remove the front, glass, and log holder (if applicable) Break the gas supply at the control valve. Unscrew the burner assembly and take them out of the combustion chamber. Fig 8.1 Logburner Spectra Frameless > > > >...
  • Page 23 Pilot assembly 37001043 Thermocouple 37002033 Bougie 06017301 Embers 20793400 Spraypaint outside 09000014 Spraypaint inside 09000008 Appendix II: Technical specifications SPECTRA FRAMELESS Logburner Logburner Country UK/IRL UK/IRL Cat. II2H3+ II2H3+ Appliancetype C11 of C31 C11 of C31 Reference gas Input (nett)