Faber SILVA B11 Installation Manual And User's Manual

Open flue built-in fireplaces
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Saturnus 8
NL-8448 CC Heerenveen
Postbus 219
NL-8440 AE Heerenveen
T. +31(0)513 656500
F. +31(0)513 656501
SILVA B11
SPECTRA B11
open flue built-in fireplaces
installation guide and user manual

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Faber SILVA B11

  • Page 1 SILVA B11 SPECTRA B11 open flue built-in fireplaces installation guide and user manual Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501...
  • Page 2: Table Of Contents

    UK/IRL CONTENTS 1. INTRODUCTION 2. SAFETY AND GENERAL INFORMATION 2.1 General safety 3. INSTALLATION REQUIREMENTS 3.1 Builders opening and surround 3.2 Flue requirements 4. INSTRUCTIONS FOR INSTALLATION 4.1 Gas connection 4.2 Preparing the appliance 4.3 Fitting the firebox 4.4 Placing the log set 5.
  • Page 3: Introduction

    UK/IRL UK/IRL 2. SAFETY AND GENERAL 1. INTRODUCTION INFORMATION Note: these instructions should be read carefully and retained for Before installation, ensure that the local distribution conditions future reference. (identification of the type gas and pressure) and the adjustment of Please leave these instructions with the user.
  • Page 4: Installation Requirements

    UK/IRL UK/IRL 3. INSTALLATION REQUIREMENTS Building Regulations and Standards issued as relevant by the Department of the Environment or the Scottish Development Note: Department. Since the appliance is a source of heat, circulation of air occurs. Therefore it is of importance that you do not use the appliance In the Republic of Ireland installation should be carried out in shortly after a renovation of the home.
  • Page 5 UK/IRL UK/IRL 3.1 Builders opening and surround (continuing) MEASUREMENTS BUILT IN AND APPLIANCE If the builders' opening is constructed of anything other than brick e.g. stud work and rendered plaster then: - Ventilate the space above the appliance (min. 1000 mm - Always supply the appliance with a DC convection set.
  • Page 6: Flue Requirements

    UK/IRL UK/IRL 3.2 Flue requirements 3.2.1 Terminal locations Site in accordance with BS 5440-1:2000 and the document J. Suitable flues and flue sizes are as follows: Flue terminal positions for pitched roofs 1. flexible stainless-steel liner or pipe (to BS715). The flue connector outer collar is for connection to a 125 mm (5 inch) internal diameter pipe or liner.
  • Page 7: Instructions For Installation

    UK/IRL UK/IRL 4. INSTRUCTIONS FOR INSTALLATION 4.1 Gas connection 4.2 Preparing the appliance 1. Installation pipes should be in accordance with BS 6891. Pipe 4.2.1 Model Silva work from the meter to the appliance must be of adequate size. 2. The complete installation including the meter must be tested for soundness and purged as described in the above code.
  • Page 8: Fitting The Firebox

    UK/IRL UK/IRL 4.2 Preparing the appliance (continuing) 4.2 Preparing the appliance (continuing) 2. Remove the glass by removing the glass clamps (B) for instance with a screwdriver. Careful when removing the glass! (see fig. 7). Wear gloves! Before placing the glass back, be sure that there are no fingerprints on the glass, it is not possible to remove those prints after you burn the appliance or a while (they will be burnt in).
  • Page 9 UK/IRL UK/IRL 4.3 Fitting the firebox (continuing) 4.3 Fitting the firebox (continuing) fig. 8 6. Secure the vent connector unit to the flue pipe or chimney liner. The flue connector outer collar is for connection to a 125 mm (5 inch) internal diameter pipe or liner. The inner collar is for connection to a 100 mm internal pipe or liner (see fig.
  • Page 10: Placing The Log Set

    4.4.2 Model Spectra (flatfibre burner) To guarantee good combustion, the log set may only be installed in the way specified by Faber International. Any other arrangement can lead to soot on logs or window. Do not use the fire with broken or missing logs.
  • Page 11: Remote Control

    To guarantee good combustion, the log set may only be installed in 5.1 Remote control (if applicable) the way specified by Faber International. Any other arangement can lead to soot on logs or window. Do not use the fire with broken or The remote control is only meant to regulate the flames, it functions missing logs.
  • Page 12: Commisioning

    UK/IRL UK/IRL UK/IRL UK/IRL 6. COMMISSIONING (functional checks) 6.1. Check pilot ignition 1. Push in and turn the control knob (A) anticlockwise to the setting (small flame). You will hear a tick meaning there is ignition. Hold the knob in and wait for a few seconds while the air is purged.
  • Page 13: Spillage Test

    This monitoring system (TTB) must not be adjusted, bypassed or put out of operation. This TTB, or any of its parts, must only be exchanged using Faber International authorised parts.
  • Page 14: Handing Over

    Never place extra elements of any kind into the combustion chamber. To guarantee good combustion, the log set may only be installed in the way specified by Faber International. Any other arrangement can lead to soot on logs or window. Do not use the fire with broken or...
  • Page 15 UK/IRL UK/IRL 8.1.1 Cleaning the glass 8.1.3 Burner tray assembly log burner Depending on the intensity of use, you can get a deposit on the 1. Remove the front, glass, log set, grid and burner tray cover. glass. This can be removed with a special non abrasive ceramic glass 2.
  • Page 16 UK/IRL UK/IRL 8.1.6 Burner tray assembly flatfiber burner 8.1.7 Pilot/thermocouple assembly 1. Remove the front, glass and log holder (if applicable). - Remove the burner tray (see 8.1.3). 2. Break the gas supply at the control valve. - Remove the lead from the pilot spark electrode. 3.
  • Page 17 UK/IRL UK/IRL UK/IRL INDEX 1 LIST OF SPARE PARTS 8.1.9 Combustion test A BS7967 combustion analysis check should be carried out using an analyser to BS7927 positioned in the flue outlet, or draft diverter. Silva Spectra Spectra log burner A Ratio of CO/CO2 should be less than 0.01 within 30 minutes. Description Company part Company part...
  • Page 18: User Guide

    UK/IRL UK/IRL UK/IRL INDEX 2 TECHNICAL DATA Country UK/IRL UK/IRL UK/IRL Category II2H3+ II2H3+ Appliance Silva Spectra Spectra Log burner Model type BS11 BS11 BS11 Reference gas Input (nett) Efficiency class Inlet pressure mbar Gas rate (15° C / 1013 mbar) m3/h 0.57 0.24 Reference burner pressure...
  • Page 19: Safety Instructions For The User

    UK/IRL UK/IRL 9. SAFETY INSTRUCTIONS FOR THE USER 9.1 General safety instructions Important A suitable Fireguard conforming to BS6539 and BS6778 should be If a gas leak is found or suspected, turn off the gas supply at the used with this appliance to protect children, the elderly or infirm. meter and contact your installer or gas emergency service.
  • Page 20: Controling The Appliance

    UK/IRL UK/IRL 10. CONTROLLING THE APPLIANCE 10.1 Lighting the fire Once gas is available at the pilot, continued rotation anti-clockwise will cause the piezo igniter to spark. This is accompanied by a click If the main burner or pilot light are extinguished for any reason, do at the valve and should result in the pilot burner igniting.
  • Page 21: Remote Control Version

    UK/IRL UK/IRL 10.3 To extinguish 10.4.1 To light 1. Push in and turn the control knob (A) from { anticlockwise to 1. For the main burner turn the control knob B clockwise to position {. the setting (small flame). You will hear a ignition click. Check that the pilot is lit (if not repeat).
  • Page 22 UK/IRL UK/IRL 10.4.3 Setting the right transmission code 10.4.4 Changing the batteries (continuing) The receiver has to learn the code from the transmitter, which is already done at the factory. However the code disappears if the Remote control receiver is disconnected from the mains for a longer period. 1.
  • Page 23: Cleaning And Service Instructions

    UK/IRL UK/IRL UK/IRL UK/IRL 11. CLEANING AND SERVICE 12. DISPOSAL OF THE PACKAGING INSTRUCTIONS AND THE APPLIANCE Important: The appliance packaging is recyclable. The packaging could include Turn off the fire and allow it to cool down before the following materials: commencing cleaning.
  • Page 24 SILVA B11 (Einbau)-Gasofen Bedienungs- und Installationsanleitung Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501...
  • Page 25 7.4 Fernbedienung (wenn zutreffend) 8. WARTUNG UND REINIGUNG 8.1 Reinigung des Brenners 8.2 Reinigung der Sichtscheibe 8.3 Reinigen der Zierleiste 9. STÖRUNG 10. ENTSORGUNG DER VERPACKUNG UND DES GERÄTES ANLAGE 1 Ersatzteilliste Silva B11 ANLAGE 2 Technische Daten Silva B11 DE 1...
  • Page 26: Vorwort De

    1. VORWORT 2. EINFÜHRUNG Zu diesem Ofen erhalten Sie eine Bedienungs- und In dieser Bedienungs- und Installationsanleitung finden Sie neben Installationsanleitung. Außer Informationen über den Gebrauch enthält Informationen über die Aufstellung, Bedienung und Wartung des Sie auch Ratschläge über Sicherheitsvorkehrungen und Wartung und Gasofens auch Empfehlungen über die Bedienungssicherheit.
  • Page 27: Sicherheitsanweisungen

    3. SICHERHEITSANWEISUNGEN Da ein Ofen eine Wärmequelle ist, die für die Zirkulation der Luft im Aufstellungsraum sorgt, ist es wichtig, dass Sie den Ofen nicht kurz nach einem Umbau heizen, da Feuchte und noch nicht erhärtete Farbe Das Gerät muss von einem anerkannten Installateur gemäß und getrockneter Lack aufgrund der natürlichen Luftzirkulation Installationsanweisung des Herstellers und den geltenden Vorschriften angesaugt werden und sich auf kalten Flächen ablagern.
  • Page 28: Vorbereitung

    4. VORBEREITUNG - Stimmen Sie die Größe der Einbauöffnung auf die Vermaßung des Einbauofens ab. Isolieren Sie das Gerät mit keramischem Isoliermaterial (siehe Abb. 1: Maßskizze). 4.1 ANSCHLUSS AN DIE GASLEITUNG - Beim Einbau ist für eine offene Fuge von ca. 3 mm rund um den - Sorgen Sie für einen Gasanschluss G3/8”...
  • Page 29: Vorbereitende Arbeiten

    5. AUFSTELLUNG DES EINBAUOFENS 4.4 VORBEREITENDE ARBEITEN 1. Nehmen Sie den Ofen aus der Verpackung. 5.1 INSTALLATION DES EINBAUOFENS 1. Stellen Sie das Gehäuse des Ofens in der Nische auf. 2. Montieren Sie das flexible Rohr auf den Rohrmund. Abb. 5 3.
  • Page 30: Einlegen Des Holzsets

    5.2 EINLEGEN DES HOLZSETS Beachten Sie: Um eine gute Verbrennung zu gewährleisten, darf das Holzset nur auf die vorgeschriebene Weise eingelegt werden (siehe Abb. 10). Eine andere Aufstellung kann zum Rußen führen. Abb. 7 7. Verbinden Sie das TRS-Kabel mit der TRS-Einrichtung (siehe Abb. 8.
  • Page 31: Service

    4. Nehmen Sie die Abdeckplatte aus dem Verbrennungsraum heraus. Führen Sie obenstehende Handlungen in umgekehrter Reihenfolge aus. Die Zündflammeneinheit darf nur durch das von FABER 5. Lösen Sie die Verschraubung der Bodenplatte und nehmen Sie die International angegebene Modell ersetzt werden.
  • Page 32: Regelarmatur

    7. BEDIENUNG 6.2 REGELARMATUR A. Druckregler Brennerdruck 7.1 HANDBEDIENUNG B. Einstellschraube Zündbrenner C. Druckmessnippel Anschlussdruck D. Druckmessnippel Düsendruck Der Regelblock befindet sich hinter der Tür. E. Kleinstelldüse Der Gasofen hat zwei Bedienungsschalter. Mit Bedienungsschalter A können Sie den Brenner anzünden. Mit Bedienungsschalter B können Sie die Brennerleistung einstellen (siehe Abb.
  • Page 33: Hauptbrenner

    Mögliche Ursachen für ein Erlöschen der Dauerzündflamme sind: 7.4.1 Inbetriebnahme - Bedienungsfehler; 1. Verbinden Sie den Netzadapter mit dem Empfangsteil. - Einschalten der Sicherung durch schlechten Schornsteinzug; Achtung: Kontrollieren Sie, ob der Adapter auf die richtige - Fehler im Zündbrennersystem. Spannung (4,5 V) eingestellt ist.
  • Page 34 6. Drücken Sie die MOD-Taste auf dem Empfangsteil des Ofens und 7.4.3 Batterien austauschen halten Sie diese Taste ein paar Sekunden gedrückt. Die Die Batterien von Empfänger und Fernbedienung haben eine Kontrollampe leuchtet kontinuierlich. Wiederholen Sie diesen ungefähre Lebensdauer von einem Jahr. Nachstehend lesen Sie, wie Schritt, wenn dies nicht der Fall sein sollte.
  • Page 35: Wartung Und Reinigung

    8. WARTUNG UND REINIGUNG 9. STÖRUNG Achtung STÖRUNG URSACHE ABHILFE Das Gerät muss jährlich von einem anerkannten Installateur gereinigt und kontrolliert werden. Ofen geht nicht an - Luft in der Zufuhrleitung. - Entlüften. Kontrolle über: - Dichte des Gas-, Verbrennungsproduktkreises; oder aus.
  • Page 36: Entsorgung Der Verpackung Und Des Gerätes

    04508000 2. Seitenverkleidung Stein Silva 09527800 3. Rückseitenverkleidung Stein Silva 09527900 Die Verpackung des Gerätes kann recycelt werden. 4. Holzblocksatz 6-teilig Silva B11 20772900 Die Verpackung kann folgende Bestandteile enthalten: 5. Schnappverschluss 24555913 28103900 - Pappe; 6. Fernbedienungs-Regeleinrichtung RF hoch 20603900 - FCKW-freier Schaumstoff (weich);...
  • Page 37: Anlage 2

    Anlage 2 Technische Daten SILVA B11 Land / country / Land / pays Categorie / category / Kategorie / catégorie I2E+ I2ELL H group I2ELL l group IH/S I2E+ Toesteltype / model type / Gerätetyp / Type d'appareil B11BS B11BS...

This manual is also suitable for:

Spectra b11

Table of Contents