UK/IRL CONTENTS 1. INTRODUCTION 2. SAFETY AND GENERAL INFORMATION 2.1 General safety 3. INSTALLATION REQUIREMENTS 3.1 Builders opening and surround 3.2 Flue requirements 4. INSTRUCTIONS FOR INSTALLATION 4.1 Gas connection 4.2 Preparing the appliance 4.3 Fitting the firebox 4.4 Placing the log set 5.
UK/IRL UK/IRL 2. SAFETY AND GENERAL 1. INTRODUCTION INFORMATION Note: these instructions should be read carefully and retained for Before installation, ensure that the local distribution conditions future reference. (identification of the type gas and pressure) and the adjustment of Please leave these instructions with the user.
UK/IRL UK/IRL 3. INSTALLATION REQUIREMENTS Building Regulations and Standards issued as relevant by the Department of the Environment or the Scottish Development Note: Department. Since the appliance is a source of heat, circulation of air occurs. Therefore it is of importance that you do not use the appliance In the Republic of Ireland installation should be carried out in shortly after a renovation of the home.
Page 5
UK/IRL UK/IRL 3.1 Builders opening and surround (continuing) MEASUREMENTS BUILT IN AND APPLIANCE If the builders' opening is constructed of anything other than brick e.g. stud work and rendered plaster then: - Ventilate the space above the appliance (min. 1000 mm - Always supply the appliance with a DC convection set.
UK/IRL UK/IRL 3.2 Flue requirements 3.2.1 Terminal locations Site in accordance with BS 5440-1:2000 and the document J. Suitable flues and flue sizes are as follows: Flue terminal positions for pitched roofs 1. flexible stainless-steel liner or pipe (to BS715). The flue connector outer collar is for connection to a 125 mm (5 inch) internal diameter pipe or liner.
UK/IRL UK/IRL 4. INSTRUCTIONS FOR INSTALLATION 4.1 Gas connection 4.2 Preparing the appliance 1. Installation pipes should be in accordance with BS 6891. Pipe 4.2.1 Model Silva work from the meter to the appliance must be of adequate size. 2. The complete installation including the meter must be tested for soundness and purged as described in the above code.
UK/IRL UK/IRL 4.2 Preparing the appliance (continuing) 4.2 Preparing the appliance (continuing) 2. Remove the glass by removing the glass clamps (B) for instance with a screwdriver. Careful when removing the glass! (see fig. 7). Wear gloves! Before placing the glass back, be sure that there are no fingerprints on the glass, it is not possible to remove those prints after you burn the appliance or a while (they will be burnt in).
Page 9
UK/IRL UK/IRL 4.3 Fitting the firebox (continuing) 4.3 Fitting the firebox (continuing) fig. 8 6. Secure the vent connector unit to the flue pipe or chimney liner. The flue connector outer collar is for connection to a 125 mm (5 inch) internal diameter pipe or liner. The inner collar is for connection to a 100 mm internal pipe or liner (see fig.
4.4.2 Model Spectra (flatfibre burner) To guarantee good combustion, the log set may only be installed in the way specified by Faber International. Any other arrangement can lead to soot on logs or window. Do not use the fire with broken or missing logs.
To guarantee good combustion, the log set may only be installed in 5.1 Remote control (if applicable) the way specified by Faber International. Any other arangement can lead to soot on logs or window. Do not use the fire with broken or The remote control is only meant to regulate the flames, it functions missing logs.
UK/IRL UK/IRL UK/IRL UK/IRL 6. COMMISSIONING (functional checks) 6.1. Check pilot ignition 1. Push in and turn the control knob (A) anticlockwise to the setting (small flame). You will hear a tick meaning there is ignition. Hold the knob in and wait for a few seconds while the air is purged.
This monitoring system (TTB) must not be adjusted, bypassed or put out of operation. This TTB, or any of its parts, must only be exchanged using Faber International authorised parts.
Never place extra elements of any kind into the combustion chamber. To guarantee good combustion, the log set may only be installed in the way specified by Faber International. Any other arrangement can lead to soot on logs or window. Do not use the fire with broken or...
Page 15
UK/IRL UK/IRL 8.1.1 Cleaning the glass 8.1.3 Burner tray assembly log burner Depending on the intensity of use, you can get a deposit on the 1. Remove the front, glass, log set, grid and burner tray cover. glass. This can be removed with a special non abrasive ceramic glass 2.
Page 16
UK/IRL UK/IRL 8.1.6 Burner tray assembly flatfiber burner 8.1.7 Pilot/thermocouple assembly 1. Remove the front, glass and log holder (if applicable). - Remove the burner tray (see 8.1.3). 2. Break the gas supply at the control valve. - Remove the lead from the pilot spark electrode. 3.
Page 17
UK/IRL UK/IRL UK/IRL INDEX 1 LIST OF SPARE PARTS 8.1.9 Combustion test A BS7967 combustion analysis check should be carried out using an analyser to BS7927 positioned in the flue outlet, or draft diverter. Silva Spectra Spectra log burner A Ratio of CO/CO2 should be less than 0.01 within 30 minutes. Description Company part Company part...
UK/IRL UK/IRL 9. SAFETY INSTRUCTIONS FOR THE USER 9.1 General safety instructions Important A suitable Fireguard conforming to BS6539 and BS6778 should be If a gas leak is found or suspected, turn off the gas supply at the used with this appliance to protect children, the elderly or infirm. meter and contact your installer or gas emergency service.
UK/IRL UK/IRL 10. CONTROLLING THE APPLIANCE 10.1 Lighting the fire Once gas is available at the pilot, continued rotation anti-clockwise will cause the piezo igniter to spark. This is accompanied by a click If the main burner or pilot light are extinguished for any reason, do at the valve and should result in the pilot burner igniting.
UK/IRL UK/IRL 10.3 To extinguish 10.4.1 To light 1. Push in and turn the control knob (A) from { anticlockwise to 1. For the main burner turn the control knob B clockwise to position {. the setting (small flame). You will hear a ignition click. Check that the pilot is lit (if not repeat).
Page 22
UK/IRL UK/IRL 10.4.3 Setting the right transmission code 10.4.4 Changing the batteries (continuing) The receiver has to learn the code from the transmitter, which is already done at the factory. However the code disappears if the Remote control receiver is disconnected from the mains for a longer period. 1.
UK/IRL UK/IRL UK/IRL UK/IRL 11. CLEANING AND SERVICE 12. DISPOSAL OF THE PACKAGING INSTRUCTIONS AND THE APPLIANCE Important: The appliance packaging is recyclable. The packaging could include Turn off the fire and allow it to cool down before the following materials: commencing cleaning.
Page 24
SILVA B11 (Einbau)-Gasofen Bedienungs- und Installationsanleitung Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501...
Page 25
7.4 Fernbedienung (wenn zutreffend) 8. WARTUNG UND REINIGUNG 8.1 Reinigung des Brenners 8.2 Reinigung der Sichtscheibe 8.3 Reinigen der Zierleiste 9. STÖRUNG 10. ENTSORGUNG DER VERPACKUNG UND DES GERÄTES ANLAGE 1 Ersatzteilliste Silva B11 ANLAGE 2 Technische Daten Silva B11 DE 1...
1. VORWORT 2. EINFÜHRUNG Zu diesem Ofen erhalten Sie eine Bedienungs- und In dieser Bedienungs- und Installationsanleitung finden Sie neben Installationsanleitung. Außer Informationen über den Gebrauch enthält Informationen über die Aufstellung, Bedienung und Wartung des Sie auch Ratschläge über Sicherheitsvorkehrungen und Wartung und Gasofens auch Empfehlungen über die Bedienungssicherheit.
3. SICHERHEITSANWEISUNGEN Da ein Ofen eine Wärmequelle ist, die für die Zirkulation der Luft im Aufstellungsraum sorgt, ist es wichtig, dass Sie den Ofen nicht kurz nach einem Umbau heizen, da Feuchte und noch nicht erhärtete Farbe Das Gerät muss von einem anerkannten Installateur gemäß und getrockneter Lack aufgrund der natürlichen Luftzirkulation Installationsanweisung des Herstellers und den geltenden Vorschriften angesaugt werden und sich auf kalten Flächen ablagern.
4. VORBEREITUNG - Stimmen Sie die Größe der Einbauöffnung auf die Vermaßung des Einbauofens ab. Isolieren Sie das Gerät mit keramischem Isoliermaterial (siehe Abb. 1: Maßskizze). 4.1 ANSCHLUSS AN DIE GASLEITUNG - Beim Einbau ist für eine offene Fuge von ca. 3 mm rund um den - Sorgen Sie für einen Gasanschluss G3/8”...
5. AUFSTELLUNG DES EINBAUOFENS 4.4 VORBEREITENDE ARBEITEN 1. Nehmen Sie den Ofen aus der Verpackung. 5.1 INSTALLATION DES EINBAUOFENS 1. Stellen Sie das Gehäuse des Ofens in der Nische auf. 2. Montieren Sie das flexible Rohr auf den Rohrmund. Abb. 5 3.
5.2 EINLEGEN DES HOLZSETS Beachten Sie: Um eine gute Verbrennung zu gewährleisten, darf das Holzset nur auf die vorgeschriebene Weise eingelegt werden (siehe Abb. 10). Eine andere Aufstellung kann zum Rußen führen. Abb. 7 7. Verbinden Sie das TRS-Kabel mit der TRS-Einrichtung (siehe Abb. 8.
4. Nehmen Sie die Abdeckplatte aus dem Verbrennungsraum heraus. Führen Sie obenstehende Handlungen in umgekehrter Reihenfolge aus. Die Zündflammeneinheit darf nur durch das von FABER 5. Lösen Sie die Verschraubung der Bodenplatte und nehmen Sie die International angegebene Modell ersetzt werden.
7. BEDIENUNG 6.2 REGELARMATUR A. Druckregler Brennerdruck 7.1 HANDBEDIENUNG B. Einstellschraube Zündbrenner C. Druckmessnippel Anschlussdruck D. Druckmessnippel Düsendruck Der Regelblock befindet sich hinter der Tür. E. Kleinstelldüse Der Gasofen hat zwei Bedienungsschalter. Mit Bedienungsschalter A können Sie den Brenner anzünden. Mit Bedienungsschalter B können Sie die Brennerleistung einstellen (siehe Abb.
Mögliche Ursachen für ein Erlöschen der Dauerzündflamme sind: 7.4.1 Inbetriebnahme - Bedienungsfehler; 1. Verbinden Sie den Netzadapter mit dem Empfangsteil. - Einschalten der Sicherung durch schlechten Schornsteinzug; Achtung: Kontrollieren Sie, ob der Adapter auf die richtige - Fehler im Zündbrennersystem. Spannung (4,5 V) eingestellt ist.
Page 34
6. Drücken Sie die MOD-Taste auf dem Empfangsteil des Ofens und 7.4.3 Batterien austauschen halten Sie diese Taste ein paar Sekunden gedrückt. Die Die Batterien von Empfänger und Fernbedienung haben eine Kontrollampe leuchtet kontinuierlich. Wiederholen Sie diesen ungefähre Lebensdauer von einem Jahr. Nachstehend lesen Sie, wie Schritt, wenn dies nicht der Fall sein sollte.
8. WARTUNG UND REINIGUNG 9. STÖRUNG Achtung STÖRUNG URSACHE ABHILFE Das Gerät muss jährlich von einem anerkannten Installateur gereinigt und kontrolliert werden. Ofen geht nicht an - Luft in der Zufuhrleitung. - Entlüften. Kontrolle über: - Dichte des Gas-, Verbrennungsproduktkreises; oder aus.
Anlage 2 Technische Daten SILVA B11 Land / country / Land / pays Categorie / category / Kategorie / catégorie I2E+ I2ELL H group I2ELL l group IH/S I2E+ Toesteltype / model type / Gerätetyp / Type d'appareil B11BS B11BS...