Power Meter
4422
Operation Manual
©
Copyright 2017
by Bird Electronic Corporation
Instruction Book Part Number 920-4422 Rev. A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4422 and is the answer not in the manual?

Questions and answers

Summary of Contents for BIRD 4422

  • Page 1 Power Meter 4422 Operation Manual © Copyright 2017 by Bird Electronic Corporation Instruction Book Part Number 920-4422 Rev. A...
  • Page 2: Safety Precautions

    Power Meter 4422 Safety Precautions The following are general safety precautions that are not necessarily related to any specific part or procedure, and  do not necessarily appear elsewhere in this publication. These precautions must be thoroughly understood and  apply to all phases of operation and maintenance. WARNING Keep Away From Live Circuits Operating Personnel must at all times observe general safety precautions. Do not  replace components or make adjustments to the inside of the test equipment with the  high voltage supply turned on. To avoid casualties, always remove power. WARNING Do Not Service Or Adjust Alone Under no circumstances should any person reach into an enclosure for the purpose of  service or adjustment of equipment except in the presence of someone who is capable  of rendering aid. WARNING Safety Earth Ground An uninterruptible earth safety ground must be supplied from the main power source  to test instruments. Grounding one conductor of a two conductor power cable is not  sufficient protection. Serious injury or death can occur if this grounding is not properly  supplied. WARNING Resuscitation Personnel working with or near high voltages should be familiar with modern methods  of resuscitation. WARNING Remove Power Observe general safety precautions. Do not open the instrument with the power on.
  • Page 3: Safety Symbols

    Safety Precautions Safety Symbols WARNING Warning notes call attention to a procedure, which if not correctly performed, could  result in personal injury. CAUTION Caution notes call attention to a procedure, which if not correctly performed, could  result in damage to the instrument. Note: Calls attention to supplemental information. Safety Symbols Used on the Equipment Pinch Point The 4422 Power Meter is designed to be opened for use. When closing for storage/transport  there is a possibility of pinching fingers, hands, or cabling. Keep items clear of chassis when clos‐ ing power meter.
  • Page 4: Warning Statements

    Power Meter 4422 Warning Statements The following safety warnings appear in the text where there is danger to operating and maintenance personnel and  are repeated here for emphasis. WARNING Pinch Point.  Hold the 4422 Power Meter chassis by the handle when lowering to the stowed  position.  Keep hands, fingers, and electrical cords clear of the outside edge of the chassis. See page 6 WARNING Before connecting the power sensor to a transmission line, refer to the power sensor  instruction book. Note the potential hazard when working with RF power. See page 7 WARNING To avoid personal injury, disconnect the power cord from the AC line before  performing any maintenance. See page 10 WARNING The Bird 4422 contains no user‐serviceable parts.  Do not remove its cover. See page 10...
  • Page 5: Caution Statements

    Safety Precautions Caution Statements The following equipment cautions appear in the text and are repeated here for emphasis. CAUTION are for air convection and Do not block air flow. The vents on the unit  must not be  obstructed. See page 4 CAUTION If Wall Mounting the 4422 Power Meter, care should be taken to avoid any movement  of the chassis that could separate the unit from the hardware used to hang the Power  Meter. If the unit lifts off the hardware it may be damaged by falling. See page 5 CAUTION 4421B540‐2 must be disconnected from the power supply when connecting or  disconnecting the power sensor. See page 7 CAUTION Do not store at temperatures below ‐20° C (‐4° F) or above 60° C (140° F). Equipment damage may result. See page 14...
  • Page 6: Safety Statements

    Power Meter 4422 Safety Statements USAGE ANY USE OF THIS INSTRUMENT IN A MANNER NOT SPECIFIED BY THE MANUFACTURER MAY IMPAIR THE INSTRUMENT’S SAFETY PROTECTION. EL USO DE ESTE INSTRUMENTO DE MANERA NO ESPECIFICADA POR EL FABRICANTE, PUEDE ANULAR LA PROTECCIÓN DE SEGURIDAD DEL INSTRUMENTO.
  • Page 7 Safety Precautions SERVICE SERVICING INSTRUCTIONS ARE FOR USE BY SERVICE - TRAINED PERSONNEL ONLY. TO AVOID DANGEROUS ELECTRIC SHOCK, DO NOT PERFORM ANY SERVICING UNLESS QUALIFIED TO DO SO. SERVICIO LAS INSTRUCCIONES DE SERVICIO SON PARA USO EXCLUSIVO DEL PERSONAL DE SERVICIO CAPACITADO.
  • Page 8: About This Manual

    Power Meter 4422 About This Manual This manual covers the operating & maintenance instructions for the following models: 4422 Changes to this Manual We have made every effort to ensure this manual is accurate. If you discover any errors, or if you have suggestions  for improving this manual, please send your comments to our Solon, Ohio factory. This manual may be periodically  updated. When inquiring about updates to this manual refer to the part number and revision on the title page. Chapter Layout Introduction — Describes the features of the Power Meter. Setup — Includes unpacking and equipment setup. Operating Instructions — Identifies steps required to power on, use, and power off the Power Meter. Troubleshooting — Provides limited troubleshooting instructions for commonly encountered problems.  Maintenance — Lists routine maintenance tasks as well as storage and shipping instructions. Specifications — Provides the specifications for the Bird Power Meter.
  • Page 9: Table Of Contents

    Chapter 6 Specifications ............15 Bird 4422 Power Meter Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Bird 4422 Power Meter Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
  • Page 10: Chapter 1 Introduction

    Chapter 1 Introduction The Bird 4422 Power Meter is used with Bird power sensors to measure RF power. The 4422 Power Meter is a Panel  PC running Bird’s Virtual Power Meter (VPM) Software. For instructions regarding the VPM3 software, refer to the  VPM3 Operation Manual (920‐VPM3). General Description The 4422 Power Meter is designed to be used with Bird’s full line of USB compatible Power Sensors. The 4422 is  equipped with a touchscreen interface. Figure 1 Bird 4422 Power Meter Assembly Table 1 - Compatible Power Sensors Sensor Type Bird Model Number CONNECTION Wideband Power 5012, 5016, 5017, 5018, 5019 Sensors (WPS) 7020 Terminating Power...
  • Page 11: Controls And Indicators

    Displays Power Sensor information and acts as the user Display/Touch Screen interface. Latches Secures the 4422 Power Meter when in the closed position. Carry handle for transporting the 4422 Power Meter when in Handle the closed position. Power status (green) Illuminates when power is applied to the unit.
  • Page 12 Provides the AC to DC interface for power to the AC Power Supply 4422 Power Meter. Air Vent Rear air vent. Cable opening for use when 4422 Power Meter is Cable Exit operated in the closed position. Locks the chassis in the open position, once open Multi-position...
  • Page 13: Chapter 2 Setup

     If the shipping container is not damaged, unpack the unit. Save shipping materials for repackaging. 3. Inspect unit for visual signs of damage.  Note: If there is damage, immediately notify the shipping carrier and Bird Electronic Corporation. Setup Setup consists of three basic steps: moving the unit into position, connecting AC power and attaching a Bird Power  Sensor. The 4422 Power Meter may also be wall mounted and operated with the chassis closed. CAUTION are for air convection and Do not block air flow. The vents on the unit  must not be  obstructed.  Use the in a dry, dust‐free environment.  Note: Do not use outdoors or in areas of condensing humidity.  Allow unobstructed air flow around the unit.  The AC power supply required is 100 ‐ 240 V @ 50 ‐ 60 Hz, 1.  1. Place the 4422 Power Meter on a stable work area. 2. Release latches and raise the Power Meter into viewing position. Figure 4 Opening the Power Meter 3. Connect Power Cord to Power supply. 4. Feed USB Cable through Cable Access in Power Meter Front Panel.
  • Page 14: Wall Mounting

    Power Meter 4422 Wall Mounting The 4422 Power Meter may be wall mounted if desired. There are two key holes located in the base of the 4422  Power Meter for use in wall mounting. See Figure 5 on page 5. CAUTION If Wall Mounting the 4422 Power Meter, care should be taken to avoid any movement  of the chassis that could separate the unit from the hardware used to hang the Power  Meter. If the unit lifts off the hardware it may be damaged by falling. 1. Identify location. (11.1 lbs (5035 g)) 2. Install two screws capable of supporting the full weight  of the Power Meter. See Figure 5 for  dimensions for locating the fasteners. 3. Remove the four rubber feet from the unit. 4. Install the 4422 Power on the screws. Figure 5 Wall Mounting Dimensions...
  • Page 15: Chapter 3 Operating Instructions

    Chapter 3 Operating Instructions Normal Operation Power On 1. Connect the Bird 4422 power meter to AC Power Supply. Note: If the unit is wall mounted, release the latches and carefully lower the front panel to access the  power button, close and latch the front panel after power is applied. 2. Press Power button on the Bird 4422 power meter rear panel. 3. Wait for VPM3 software to display before continuing. Power Off 1. Press Power button on the Bird 4422 power meter rear panel to power down the 4422 Power Meter. Note: Wait for complete power down before continuing 2. Disconnect the AC power supply. 3. Disconnect USB cable from Power Sensor. WARNING Pinch Point.  Hold the 4422 Power Meter chassis by the handle when lowering to the stowed  position.  Keep hands, fingers, and electrical cords clear of the outside edge of the chassis. 4. Raise the Power Meter to the farthest forward position then slowly lower to the fully stowed position. 5. Close storage latches. Note: Ensure latches are closed and locked before transporting the 4422 using the carry handle. Touch panel Operation The 4422 has a touch screen and is designed to be used without a keyboard or mouse.
  • Page 16: Usb Power Sensor Operation

    USB Power Sensor operation WARNING Before connecting the power sensor to a transmission line, refer to the power sensor  instruction book. Note the potential hazard when working with RF power. 1. If required, connect Bird Power Sensor to RF Transmission Line, following instructions in the Power Sensor man‐ ual. 2. Connect the Power Meter USB cable to the Power Sensor. Note: VPM will automatically detect the power sensor. 3. Apply RF power to the Power Sensor. 4. Make measurements. Refer to the VPM Software Operation Manual (920‐VPM3). The VPM3 manual is available  on www.birdrf.com. 4421B540-2 Module Power Sensor operation (Bird 402X Power Sensors) WARNING Before connecting the power sensor to a transmission line, refer to the power sensor  instruction book. Note the potential hazard when working with RF power. CAUTION 4421B540‐2 must be disconnected from the power supply when connecting or  disconnecting the power sensor. 1. If required, connect Bird Power Sensor to RF Transmission Line, following instructions in the Power Sensor man‐ ual. 2. Connect a sensor cable (supplied with sensor) between the 4421B540‐2 and the RF power sensor. 3. Connect the USB cable from the 4422 Power Meter to the 4421B540‐2.
  • Page 17: Optional Configurations

    Operating Instructions Optional Configurations Multiple Sensor Operation It is possible to connect up to four Power Sensors directly to the 4422 Power Meter simultaneously. The Bird 4422  has a total of four USB ports.  To attach additional Power Sensors to the 4422 Power Meter, perform the following: 1. Remove the Interface Connector Cover. See "Remove Interface Connector Cover" on page 13. 2. Obtain additional USB cables, Type A to Type B. See "Replacement Parts" on page 17. 3. Connect Power Sensors to the 4422 Power Meter as described in "USB Power Sensor operation" on page 7 or  "4421B540‐2 Module Power Sensor operation (Bird 402X Power Sensors)" on page 7. Ethernet Connection It is possible to connect the 4422 Power Meter to an Ethernet Network. To connect the 4422 Power Meter, perform  the following: 1. Remove the Interface Connector Cover. See "Remove Interface Connector Cover" on page 13. 2. Obtain a standard “straight” Ethernet cable. 3. Plug one end of the Ethernet cable into to back of the 4422 Power Meter. 4. Plug the remaining end of the Ethernet cable into an available LAN connection. 5. Configure Windows 7 to enable the network connection.
  • Page 18: Chapter 4 Troubleshooting

    Chapter 4 Troubleshooting PROBLEM POSSIBLE CAUSE CORRECTION Power meter has no Is the power meter’s AC power Connect the power cord. power supply connected to an AC outlet? Is the DC supply cord Connect the power cord. connected to the Power Meters rear panel? Is the power switch on the rear Set the switch to ON.
  • Page 19: Chapter 5 Maintenance

    Chapter 5 Maintenance This chapter describes routine maintenance for service beyond this level or that in Chapter 4, Troubleshooting,  return the unit to a qualified service center. WARNING To avoid personal injury, disconnect the power cord from the AC line before  performing any maintenance. WARNING The Bird 4422 contains no user‐serviceable parts. Do not remove its cover. Routine Maintenance The Bird 4422 Power Meter requires only simple, routine maintenance.  Wipe off dust and dirt regularly. Disconnect this equipment from any AC outlet before cleaning. Use a damp  cloth. Do not use liquid or spray detergents for cleaning.  Check the connectors and cables for damage. Annual Maintenance Lubricate the following components using silicone lubricant:  Support strut  Hinges   Carry handle Touch Screen Calibration The Touch Screen has two levels of calibration available, Standard and Advanced. Standard calibration uses five  points on the screen for calibration. In most cases standard calibration will provide sufficient touch screen accuracy  for 4422 Power Meter operation. Advanced calibration uses 9, 16, or 25 points on the screen for calibration. This  option should only be required if the standard calibration does not provide sufficient accuracy. It is recommend that  a stylus be used when performing an advanced calibration. Standard Touch Screen Calibration In most cases standard touch screen calibration will provide sufficient accuracy for power meter operations.
  • Page 20 Power Meter 4422 Figure 7 PenMount Control Panel 5. Tap Standard Calibration on the Device’s Calibration Dialog Box. See Figure 8 on page 11. Figure 8 Calibration Dialog Box 6. On the Calibration Screen, press and hold a finger on each calibration point as it is displayed. See Figure 9 on  page 11. Figure 9 Standard Calibration Screen...
  • Page 21: Advanced Touch Screen Calibration

    Maintenance Advanced Touch Screen Calibration The advanced calibration is only required if the standard calibration does not provide accurate touch screen opera‐ tion. It is recommended a stylus be used when performing the advanced touch screen calibration. 1. Close the VPM3 display application by selecting File‐> Exit 2. On the desktop, double tap the "PenMount Control Panel" icon. 3. Tap PenMount6000 RS232 on the Device tab. See Figure 10 on page 12. 4. Tap Configure. Figure 10 PenMount Control Panel 5. Tap Advanced Calibration on the Device’s Calibration Dialog Box. See Figure 11 on page 12. Figure 11 Calibration Dialog Box 6. On the Calibration Screen, press and hold a stylus on each calibration point as it is displayed. See Figure 12 on  page 13.
  • Page 22: Remove Interface Connector Cover

    Power Meter 4422 Figure 12 Advanced Calibration Screen Remove Interface Connector Cover A tamper guard is installed over the Interface connectors from the factory. This reduces risk of unauthorized data  access to the 4422. If the cover is not necessary or connection of multiple sensors is desired, remove the cover as  follows: 1. Power Off the 4422 Power Meter, but do not close. See "Power Off" on page 6. 2. Cut the cable tie (2) securing the power cord to the Interface Connector Cover (3). See Figure 13 on page 13. 3. Remove four #1 cross‐tip screws (1) securing the Interface Connector Cover (3) to the Bird Power Meter. 4. Store cover and screws for re‐installation. Figure 13 Interface Connector Cover Removal...
  • Page 23: Storage And Shipment

    Maintenance Storage and Shipment Storage CAUTION Do not store at temperatures below ‐20° C (‐4° F) or above 60° C (140° F). Equipment damage may result. 1. Cover Bird 4422 Power Meter before storing to keep out dust and dirt.  2. Store in a dry, dust‐free environment where the ambient temperature will remain between –20 and +60 °C (–4  to +140 °F). 3. Disconnect Power Meter from the power source to avoid damage by transient over‐voltage. Shipment Ensure unit is closed and latched prior to packaging for shipment. Package instrument using the original shipping container. If the original shipping container is not available, use a cor‐ rugated box. Place shock absorbing material around all sides of the instrument to prevent movement during han‐ dling or shipment. Equipment packaging shall be in accordance with best commercial practices. Customer Service Any maintenance or service procedure beyond the scope of those in this chapter should be referred to a qualified  service center. If the unit needs to be returned for any reason, request an Return Material Authorization (RMA) through the Bird  Technologies website. All instruments returned must be shipped prepaid and to the attention of the RMA number. Bird Service Center 30303 Aurora Road Cleveland (Solon), Ohio 44139‐2794 Fax: (440) 248‐5426 E‐mail: bsc@birdrf.com For the location of the Sales Office nearest you, visit our Web site at: http://www.birdrf.com...
  • Page 24: Chapter 6 Specifications

    Chapter 6 Specifications Bird 4422 Power Meter Specifications Compatible Bird Power 5012, 5014, 5015, 5016, 5017, 5018, 5019, 7020, 7022, 7023, 4021, † Sensors 4022, 4023, 4024, 4025, 4027, 4028 Sensor Detection Automatic Sensor detection opens appropriate display for each sensor type.
  • Page 25: Bird 4422 Power Meter Dimensions

    (EN 55011, EN 61000-6-3, EN 61000-6-1, EN 55022, EN 55024) FCC Part 15 Class B IC ICES-003 RoHS2 per Directive 2011/65/EU †. All 402x series Precision Power Sensors require the use of the 4421B540-2 Sensor Interface Module. Bird 4422 Power Meter Dimensions...
  • Page 26: Replacement Parts

    Power Meter 4422 Replacement Parts Description Part Number Cable, USB 5A2653-6L AC Power Supply 5A2976-10-1 AC Power Cord 5A2976-10-2 Optional Accessories Description Part Number Sensor Interface Module (Converts 402x Power 4421B540-2 Sensor I/O to USB)
  • Page 27: Limited Warranty

    Limited Warranty All products manufactured by Seller are warranted to be free from defects in material and workmanship for a period  of one (1) year, unless otherwise specified, from date of shipment and to conform to applicable specifications, draw‐ ings, blueprints and/or samples. Seller’s sole obligation under these warranties shall be to issue credit, repair or  replace any item or part thereof which is proved to be other than as warranted; no allowance shall be made for any  labor charges of Buyer for replacement of parts, adjustment or repairs, or any other work, unless such charges are  authorized in advance by Seller. If Seller’s products are claimed to be defective in material or workmanship or not to conform to specifications, draw‐ ings, blueprints and/or samples, Seller shall, upon prompt notice thereof, either examine the products where they  are located or issue shipping instructions for return to Seller (transportation charges prepaid by Buyer). In the event  any of our products are proved to be other than as warranted, transportation costs (cheapest way) to and from  Seller’s plant, will be borne by Seller and reimbursement or credit will be made for amounts so expended by Buyer.  Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing  within ten days from the date of discovery of the defect. The above warranties shall not extend to any products or parts thereof which have been subjected to any misuse or  neglect, damaged by accident, rendered defective by reason of improper installation or by the performance of  repairs or alterations outside of our plant, and shall not apply to any goods or parts thereof furnished by Buyer or  acquired from others at Buyer’s request and/or to Buyer’s specifications. Routine (regularly required) calibration is  not covered under this limited warranty. In addition, Seller’s warranties do not extend to the failure of tubes, transis‐ tors, fuses and batteries, or to other equipment and parts manufactured by others except to the extent of the origi‐ nal manufacturer’s warranty to Seller. The obligations under the foregoing warranties are limited to the precise terms thereof. These warranties provide  exclusive remedies, expressly in lieu of all other remedies including claims for special or consequential damages.  SELLER NEITHER MAKES NOR ASSUMES ANY OTHER WARRANTY WHATSOEVER, WHETHER EXPRESS, STATUTORY, OR  IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS, AND NO PERSON IS AUTHORIZED TO  ASSUME FOR SELLER ANY OBLIGATION OR LIABILITY NOT STRICTLY IN ACCORDANCE WITH THE FOREGOING.