Advanced System Set Up

The system will be set to its default parameters when powered on for the first
time. The screen displays the following information in sequence and the user can
change any given value on each screen.
To change a parameter value in the program, press START/ENTER to make that
value blink. Next, change the value by pressing INC or DEC. The value will be
stored by pressing START/ENTER once.
ITEM
ITEM
Safet y
T imer
Safet y
T imer
O N
1 20Mi n
O N
1 20Mi n
Capacit y C ut-Off
Capacit y C ut-Off
O N
5 000mAH
O N
5 000mAH
Tem p C ut-Of f
Tem p C ut-Of f
5 0 ° C
1 22 ° F
O N
5 0 ° C
1 22 ° F
O N
Temperatur
e U nit
Temperatur
e U nit
C elsius
C elsius
Res t T ime
Res t T ime
CHG>DCH G
1 0Min
CHG>DCH G
1 0Min
SELECTION
SELECTION
When you start a charge process, t he
When you start a charge process, t he
integral safety timer automatically s tarts
integral safety timer automatically s tarts
running
OFF/
running
OFF/
programmed to p revent overcharge the
ON
programmed to p revent overcharge the
ON
battery i f it p roves to be faulty, or i f the
1-720 Min
(
)
battery i f it p roves to be faulty, or i f the
1-720 Min
termination circuit cannot detect the battery
(
)
termination circuit cannot detect the battery
full. The value for the safety timer should be
full. The value for the safety timer should be
generous enough to a llow a full charge of
generous enough to a llow a full charge of
the battery.
the battery.
This p rogram sets the maximum charge
This p rogram sets the maximum charge
capacity that will be supplied to the battery
capacity that will be supplied to the battery
OFF/
during charge. If the delta peak voltage is
OFF/
during charge. If the delta peak voltage is
ON
not detected nor the safety timer expired by
ON
not detected nor the safety timer expired by
(
any reason, t his feature will automatically
100-50000 mAh)
(
any reason, t his feature will automatically
100-50000 mAh)
stop the process at t he selected capacity
stop the process at t he selected capacity
value.
value.
OFF/
The battery's internal chemical reaction will
OFF/
The battery's internal chemical reaction will
ON
cause the temperature of t he battery t o
ON
cause the temperature of t he battery t o
(20 C/68 F -
rise. If the temperature limit is reached, the
(20 C/68 F -
rise. If the temperature limit is reached, the
process will be terminated.
80 C/176 F
)
process will be terminated.
80 C/176 F
)
Celsius
You can choose the temperature displayed
Celsius
You can choose the temperature displayed
by Celsius or Fahrenheit as you like.
Fahrenheit
by Celsius or Fahrenheit as you like.
Fahrenheit
A rest t ime allowing the battery t o cool
1-60Min
A rest t ime allowing the battery t o cool
down between charging/discharging cycle.
1-60Min
down between charging/discharging cycle.
DESCRIPTION
DESCRIPTION
at t he s ame time.
at t he s ame time.
This i s
This i s
39