2. LCD display list

Below list shows all LCD letter indications for both oparating mode.
In operating mode, data 003 ~ 022 and 082, 084 will be on the display according to the machine condition.
In case of non AI, non S/P control machines, date 008 ~ 022 except 017, 018, 019, 020, 021 won't come up
to show.
<Operating mode menu list>
English
name
data000
data001
data002
data003
data004
data005
data006
data007
data008
data009
data010
data011
data012
data013
data014
data015
data016
data017
data018
data019
data020
data021
data022
data082
data084
meaning and explanation
This LCD display shows the following conditions;fuel amount, water temp., engine
oil pressure, battery, glow plug, and operating hour meter.
This LCD display shows the following conditions;fuel amount, water temp., engine
speed.
This LCD display shows the following conditions;fuel amount, water temp.,
and operating hour meter.
The letter on the LCD indicates the warning of each function;fuel amount shortage
The letter on the LCD indicates the warning of low engine oil pressure
The letter on the LCD indicates the warning of low charging voltage of alternator
The letter on the LCD indicates the warning of each function; higher voltage line
connected for example, 24 V battery
The letter on the LCD indicates the warning thepossibility of engine overheating
condition EU - version only : 124 ± °C
The letter on the LCD indicates the warning ofaccel sensor line break or shortage
The letter on the LCD indicates the warning of governor sensor line break or
shortage
The letter on the LCD indicates the warning of AI motor line shortage.
The letter on the LCD indicates the warning of AI motor line break.
The letter on the LCD indicates the amount of auxiliary port flow.
The letter on the LCD indicates the warning of electrical shortage of aux. solenoid
valve left side.
The letter on the LCD indicates the warning of electrical line break of aux. sole-
noid valve left side.
The letter on the LCD indicates the warning of electrical shortage of aux. solenoid
valve right side.
The letter on the LCD indicates the warning of electrical line break of aux. sole-
noid valveright side.
The letter on the LCD indicates the warning of coolant sensor or water temp. sen-
sor fail.
The letter on the LCD indicates the warning of fuel sensor fail.
The letter on the LCD indicates the warning of 12V sensor supply line shortage.
The letter on the LCD indicates the warning of 5V sensor supply line shortage.
The letter on the LCD indicates the warning of controller error in the meter panel.
The letter on the LCD indicates the warning of AI motor being restricted by any
means.
These indicates where machine was manufactured.
This indicates that operator is suggested to lift up unload lever(safety lock lever).