MODEL
DC (heater) Operation
Refrigerator Internal Fuse
Min. Wire Size
Max. Wire Size
Min. fuse Size
Max. Fuse Size
*0-20'
**over 20'
AC Heater
Watts/Amps/Ohms
DC Heater
Watts/Amps/Ohms
Ohms reading +/- 5%
Automatic Ignition
Moisture Reduction (Divider) Heater
Interior Light
982 & 9182
983 & 9183
12 VDC required to operate and maintain the operating control.
12 volts needed to operate the DC Electric (heater) and to operate the interior light and the
moisture reduction (divider) heater.
Fuses
DC Control Voltage
3 Amp Blade Type
DC Control Voltage
3 Amp Blade Type
AC Circuit
5 Amp 3AG (Glass)
AC Circuit
5 Amp 3AG (Glass)
DC Electric (Heater)
30 Amp Blade Type
DC Supply Wire Requirements
18 AWG
18 AWG
*6 Amp
**6 Amp
**40 Amp
Heater Specifications
300 /2.7 /40.3
300 /2.7 /40.3
225/16/.87
Additional Current Draws
4
962 & 9162
DC Control Voltage
3 Amp Blade Type
AC Circuit
5 Amp 3AG (Glass)
10 AWG
18 AWG
8 AWG
18 AWG
*30 Amp
*6 Amp
**6 Amp
300 /2.7 /40.3
.50 amps
.11 to .17 amps
.60 amps
963 & 9163
DC Control Voltage
3 Amp Blade Type
AC Circuit
5 Amp 3AG (Glass)
DC Electric (Heater)
30 Amp Blade Type
10 AWG
8 AWG
*30 Amp
**40 Amp
300 /2.7 /40.3
225/16/.87