Norcold 9182 Service Manual & Parts List page 24

900 & 9100 series
Hide thumbs Also See for 9182:
Table of Contents

Advertisement

Screen No. 6 AC Heater Current
This screen displays AC current measured by the control (decimal point implied).
Figure 10
A. Identifies information screen.
B. The refrigerator control displays AC current measured by the control. Figure 10 indicates 2.9 amps.
C. Indicates AC electric mode of operation.
To verify:
1. Measure the AC current draw through the AC heater (2.7 - 2.9 Amps). The current will be +/- 10%
of the control's display.
Screen No.7-DC Input Voltage
This screen displays the measured DC (decimal point is implied) input voltage to the control.
Figure 11
A. Identifies information screen.
B. The refrigerator control displays the DC input voltage measured by the control over the range of 10.5 to 15.4 VDC. (Figure 11
indicates 12 VDC).
C. BATT will be displayed indicating DC voltage.
To verify:
1. Measure the input DC voltage at the control board. The voltage will be +/- 1.0 VDC of the control's
display.
A
B
A
B
23
C
C