Mirage IVEH121A Owner's Manual page 52

Table of Contents

Advertisement

WARNING
BEFORE PERFORMING ANY ELECTRICAL OR
WIRING WORK, TURN OFF THE MAIN POWER
TO THE SYSTEM.
1. Prepare the cable for connection:
USE THE RIGHT CABLE
• Indoor Power Cable (if applicable):
H05VV-F or H05V2V2-F
• Outdoor Power Cable: H07RN-F
• Signal Cable: H07RN-F
Minimum Cross-Sectional Area of Power
and Signal Cables
a. Using wire strippers, strip the rubber
jacket from both ends of cable to reveal
about 1.57in of the wires inside.
b. Strip the insulation from the ends of the
wires.
c. Using a wire crimper, crimp u-lugs on
the ends of the wires.
PAY ATTENTION TO LIVE WIRE
While crimping wires, make sure you clearly dis-
tinguish the Live ("L") Wire from other wires.
WARNING
ALL WIRING MUST PERFORMED STRICTLY IN
ACCORDANCE WITH THE WIRING DIAGRAM
LOCATED INSIDE THE OUTDOOR UNIT'S
WIRE COVER.
2. Unscrew the electrical wiring cover and re-
move it.
3. Unscrew the cable clamp below the terminal
block and place it to the side.
4. Match the wire colors/labels with the labels on
the terminal block, and firmly screw the u-lug of
each wire to its corresponding terminal.
5. After checking to make sure every connection
is secure, loop the wires around to prevent rain
water from flowing into the terminal.
6. Using the cable clamp, fasten the cable to the
unit. Screw the cable clamp down tightly.
7. Insulate unused wires with PVC electrical tape.
Arrange them so that they do not touch any elec-
trical or metal parts.
8. Replace the wire cover on the side of the unit,
and screw it in place.
Cover