RD 12/RD 12A
9.24
Installing the Exciter Pump
Prerequisites
Machine OFF and engine cool.
Procedure
Follow the procedure below to install the exciter pump.
1. Place a plastic sheet and a container under the machine to collect any liquid which
drains off. Dispose of this liquid in accordance with environmental protection legislation.
2. Connect the hydraulic hose to the exciter pump with the hose clamp (c).
3. Secure the exciter pump to the drive pump with two screws (b) .
4. Connect the outgoing hydraulic line (a).
5. Check the level of the hydraulic oil; add hydraulic oil as necessary.
The procedure to install the exciter pump is now complete.
wc_tx000671gb.fm
a
b
c
wc_gr004183
101
Disassembly & Assembly