4.5

CAGE WEIGH SYSTEM

4.5.1
LOAD CELL VERSION
The Niftylift HR21 Hybrid is fitted with an electronic load cell. This load cell is a moment-independent,
redundant design. This means that independent of the load position inside the cage of the machine, the
actual load is measured and if pre-configured limit values are exceeded, warnings will be activated.
"Redundant design" means that the load cell design incorporates dual channels that monitor each
other. The design of the unit meets the requirements of both EN280 and EN954-1 class III.
4.5.2
FUNCTION
The machine informs the operator, via the load cell output, of the current state of the machine with
regard to cage load. There are three output lamps: green, amber and red. The three lamps for the load
cell are located on the cage control panel (see section 4.3.1). These lamps can be interpreted as
follows:
Lamp
Constant green
Constant amber
Flashing amber
Flashing red (Safety
Warning Lamp)
4.5.3
CALIBRATION, INSPECTION AND MAINTENANCE
Calibration, maintenance and repair of the Niftylift HR21 Hybrid cage load cell requires specialist
knowledge and equipment. For this reason, no part of the Niftylift HR21 Hybrid cage-weigh
system can be adjusted, repaired or inspected by the operator.
All enquiries relating to calibration, inspection or maintenance should be directed to Niftylift or one of
Niftylift's approved dealers. Contact details are listed in Section 1.4
English/USA – 11/09
Original Instructions
Description
Load in the cage does not exceed
80% of safe working load
Load in the cage is 80-90% of
safe working load
Load in the cage is 90% of safe
working load
Load in the cage has exceeded
safe working load
Operating & Safety Instructions
Load
Machine Behaviour
value
180kg or
Normal operation
less
180kg to
Normal operation
203kg
203kg to
Normal operation
225kg
Above
Controls isolated –
225kg
safely remove excess load
to restore normal operation
HR Series
33