GE 489 Communications Manual page 62

Generator management relay
Hide thumbs Also See for 489:
Table of Contents

Advertisement

Obj
Var
1
0
1
1
1
2
2
0
2
1
2
2
10
0
10
2
12
1
20
0
20
5
20
6
21
0
21
9
21
10
30
0
30
1
30
2
30
3
30
4
32
0
32
1
32
2
32
3
32
4
50
1
60
1
60
2
60
3
60
4
80
1
58
3.
The point tables for Binary Input and Analog Input objects contain a field that defines
to which event class the corresponding static data point has been assigned.
4.
For this object, the qualifier code must specify an index of 7 only.
5.
Delay Measurement (function code 23) is supported since the relay allows for writing
the time via object 50 and it also periodically sets the "Time Synchronization Required"
Internal Indication (IIN). The IIN is set at power-up and will be set again 24 hours after
it was last cleared. The IIN is cleared when time is written as object 50 data or if IRIG-B
is enabled and relay time is updated as a result of a successful decoding of this signal.
Table CG–3: DNP Implementation Table
Object
Description
Binary Input - All Variations
Binary Input
Binary Input With Status (Note 6)
Binary Input Change - All Variations
Binary Input Change Without Time
Binary Input Change With Time
Binary Output - All Variations
Binary Output Status
Control Relay Output Block
Binary Counter - All Variations
32-Bit Binary Counter without Flag
16-Bit Binary Counter without Flag
Frozen Counter - All Variations
32-Bit Frozen Counter without Flag
16-Bit Frozen Counter without Flag
Analog Input - All Variations
32-Bit Analog Input With Flag
16-Bit Analog Input With Flag
32-Bit Analog Input Without Flag
16-Bit Analog Input Without Flag
Analog Input Change - All Variations
32-Bit Analog Input Change without Time
16-Bit Analog Input Change without Time
32-Bit Analog Input Change with Time
16-Bit Analog Input Change with Time
Time and Date
Class 0 Data (Note 2)
Class 1 Data (Note 3)
Class 2 Data (Note 3)
Class 3 Data (Note 3)
Internal Indications
No object - Cold Start
No object - Warm Start
No object - Delay Measurement (Note 5)
Request
Func Codes
Qual Codes
(Hex)
1
06
1
00, 01, 06
1
00, 01, 06
1
06, 07, 08
1
06, 07, 08
1
06, 07, 08
1
06
1
00, 01, 06
3, 4, 5, 6
17, 28
1, 7, 8, 9, 10
06
1, 7, 8, 9, 10
06
1, 7, 8, 9, 10
06
1
06
1
06
1
06
1
06
1
00, 01, 06
1
00, 01, 06
1
00, 01, 06
1
00, 01, 06
1
06, 07, 08
1
06, 07, 08
1
06, 07, 08
1
06, 07, 08
1
06, 07, 08
1, 2
07 (Note 1)
1
06
1
06, 07, 08
1
06, 07, 08
1
06, 07, 08
2
00 (Note 4)
13
14
23
489 GENERATOR MANAGEMENT RELAY – COMMUNICATIONS GUIDE
Response
Func Codes
Qual Codes
(Hex)
129
00, 01
129
00, 01
129
17, 28
129
17, 28
129
00, 01
129
17, 28
129
00, 01
129
00, 01
129
00, 01
129
00, 01
129
00, 01
129
00, 01
129
00, 01
129
00, 01
129
00, 01
129
00, 01
129
17, 28
129
17, 28
129
17, 28
129
17, 28
129
07
129
129
129
129
129

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents