Equipment Description..Whisper® Ultrasonic Leak Detector Applicable Directives ..73/23/EEC as amended by 93/68/EEC 89/336/EEC as amended by 93/68/EEC Applicable Standards .
Applications A/C Refrigerant Leaks (Any and all types of refrigerant) Locating Worn Bearings Leaks in Pneumatic Control Systems Leaks in Natural Gas, LPG Leaks Leaks in Compressed Air Systems Leaks in Vacuum Systems Line Set Leaks In Foundation/Walls Diagnosing Solenoid Operations Steam Traps Electrical Arcing Specifications...
1. Slide the power switch to the on position and rotate the “Sensitivity” control knob to the maximum clockwise position. 2. Point the Whisper in the direction of the suspected leak and scan the area by making a slow “X” (a vertical and horizontal type sweeping motion) while keeping the probe pointed in the general direction of the suspected leak.
Transmitter Accessory The Whisper Transmitter is an optional accessory which can be used with the Whisper Ultrasonic Leak Detector to locate leaks in walk-in coolers/freezers, wall and ceiling joints, around doors, windows, body seals, rubber moldings, ducts, etc. The Transmitter produces the frequency detected by the Whisper.
Warranty INFICON warrants your Whisper Ultrasonic Leak Detector to be free from defects of materials or workmanship for two years from the date of purchase. INFICON does not warrant items that deteriorate under normal use, such as power cells. In addition, INFICON does not warrant any instrument that has been subjected to misuse, negligence, or accident, or has been repaired or altered by anyone other than INFICON.
Page 8
TWO TECHNOLOGY PLACE EAST SYRACUSE, NY 13057-9714 USA Phone: +1.800.344.3304 Fax: +1.315.437-3803 Email: reachus@inficon.com www.inficon.com 074-345-P1C...
Need help?
Do you have a question about the Whisper and is the answer not in the manual?