I N S T A L L A T I O N P R O C E D U R E S
3.7

Fan unit or alarm unit (option)

3.7.1

Installing FAMO1 or FAMO1-F

Installation of the FAMO1 fan
unit or FAMO1-F alarm unit
3.7.2

FOX interface

64
Proceed as follows:
1. Locate the fixing position of the FAMO1 or FAMO1-F in the 19-inch rack
or within the ETSI adapters above the FOX subrack (refer to
and
Figure 15
respectively).
2. Lift the FAMO1 or FAMO1-F into position and secure the FAMO1 or
FAMO1-F using four M6 screws.
3. Tighten the M6 screws provisionally.
4. Fit the cable clips (21) and (22) provided with the FAMO1 or FAMO1-F
package to the left and right side of the FAMO1 or FAMO1-F front panel
(refer to
Figure
36).
End of instruction
The FAMO1 or FAMO1-F power and alarm signals are connected via the
power and alarm cable to the FOX subrack.
1

Figure 35: FAMO1 or FAMO1-F power and alarm cable

Legend:
1
Subminiature-D connector (15 way) connects to the subrack
2
Molex connector (12 way) connects to the FAMO1 or FAMO1-F
Figure 6
2
FOX615
Installation