Subrack; Installing Dupf1 (Option) - ABB FOX615 Installation & User Manual

Table of Contents

Advertisement

3.6

Subrack

3.6.1

Installing DUPF1 (option)

FOX615
Installation
The following description applies for FOX subracks with the DUPF1 dual
power supply option only. This option is required for dual source power sup-
ply of the subrack. If you do not use the DUPF1 option you can proceed with
section
Installing the FAMO1 or FAMO1-F power and alarm cable (optional)
(on page 55).
The DUPF1 is delivered in a separate package together with an additional
power cable.
The DUPF1 unit is mounted on the FOX subrack and secured with two
screws to the left and right of the DUPF1. There is no impact on the FAMO1
or FAMO1-F installation.
You must install the DUPF1 before the FOX615 subrack is installed in the
rack.
Figure 30
shows the FOX subrack with installed DUPF1 option.
I N S T A L L A T I O N P R O C E D U R E S
51