6. Restoring INDeX Remote Access Module Defaults

User's Guide
38DHB0002UKDS – Issue 2 (09/01/2002)
The Remote Access Module is supplied pre-set for operation with an
INDeX system at 9600bps.
To locally restore the Remote Access Module settings :
1. Using the serial cable (0.5m) supplied with the kit, connect the
Remote Access Module to your PC.
2. Ensure that your PC's terminal package is set to 9600bps, 8 bits, no
parity and 1 stop bit.
3. Enter the AT string:
AT&F&D0&K0Q1E0TS0=1
This sets and stores the preferred settings for INDeX operation as
module Profile 0.
The string can be broken down as follows:
&F
Restore factory defaults.
&D0
Ignore DTR.
&K0
Disable DTE flow control.
Q1
Disables results code.
E0
Echo disabled.
T
Tone dialling.
S0=1 Answer after first ring.
4. When finished with the local PC connection, enter the AT command
ATE0Q1 to switch of command echo and modem responses.
5. Disconnect the serial cable from the PC and Remote Access
Module. Reconnect the serial cable (CAB-RAM) from the INDeX
cabinet to the Remote Access Module .
(where 0 = zero).
Remote Access Module 4
Page 11