To Access Mode 1 Or 2; To Use Mode 1; To Use Mode 2; Mode 1 (And Default Situation): Monitoring Settings - Daikin LRMEQ3BY1 Installation And Operation Manual

Air-cooled refrigeration condensing unit
Hide thumbs Also See for LRMEQ3BY1:
Table of Contents

Advertisement

[
-
32
+
16
+
8
+
4
+
2
+
1]
H1P
H1P H2P H3P H4P H5P H6P H7P
(H1P ON)
0
+
0
+
0
+
0
+
0
+
1
(H2P~H7P = binary 1)
0
+
0
+
8
+
0
+
0
+
0
(H2P~H7P = binary 8)
6.1.4

To access mode 1 or 2

After the units are turned ON, the display goes to its default
situation. From there, you can access mode 1 and mode 2.
Initialisation: default situation
Turn on the power supply of the outdoor unit. After initialisation, the
display indication state will be as below (default situation when
shipped from factory).
10~12 min
a
Power ON
b
Default situation
c
LED indication when there is a malfunction
If the default situation is not displayed after 10~12 minutes, check
the malfunction code. Solve the malfunction code accordingly.
Switching between modes
Use BS1 to switch between the default situation, mode  1 and
mode 2.
a
b
c
a
Default situation (H1P OFF)
b
Mode 1 (H1P flashing)
c
Mode 2 (H1P ON)
BS1
Press BS1.
BS1 [5 s]
Press BS1 for at least 5 s.
INFORMATION
If you get confused in the middle of the process, press BS1
to return to the default situation.
6.1.5

To use mode 1

In mode 1 (and in default situation) you can read out some
information.
See
"6.1.7  Mode 1 (and default situation): Monitoring settings"  on
page 21.
Example: 7‑LEDs display – Mode 1
See
"8.1.1 To display the error codes of the latest malfunctions" on
page 24.
LRMEQ3+4BY1
Air-cooled refrigeration condensing unit
4P495373-1 – 2017.07
Description
Mode 2
Setting 1
(in mode 2)
Value 8
(in mode 2)
a
b
c
6.1.6

To use mode 2

In mode 2 you can make field settings to configure the system.
Example: 7‑LEDs display – Mode 2
You can fine‑tune the value of setting [2‑1] (= T
temperature) to 8 (= +3°C) as follows:
#
Action
1
Start from the default
situation.
2
Select mode 2.
3
Select setting 1.
("X×" depends on the setting
that you want to select.)
4
Select value 8 (= +3°C).
a: Display the current value.
b: Change until the LED
indication corresponds with
the LEDs in
"6.1.8 Mode 2:
Field settings" on
page 22.
("X×" depends on the current
value, and the value that you
want to select.)
c: Enter the value in the
system.
d: Confirm. The system starts
operating according to the
setting.
5
Quit mode 2.
6.1.7
Mode 1 (and default situation): Monitoring
settings
In mode 1 (and in default situation) you can read out some
information.
7‑LEDs display – Default situation (H1P OFF)
You can read out the error code status:
Situation
Default
Error
7‑LEDs display – Mode 1 (H1P flashing)
You can read out the following information:
Setting
(
)
[1‑14]
Shows the latest malfunction
code.
[1‑15]
Shows the 2nd last malfunction
code.
[1‑16]
Shows the 3rd last malfunction
code.
6 Configuration
target evaporating
e
Button/display
BS1 [5 s]
(= binary 1)
a
BS3 [1×]
b
BS2 [X×]
c
BS3 [1×]
d
BS3 [1×]
BS1 [1×]
LED indication
Value / Description
For more information, see
"8.1 Solving problems based on
error codes" on
page 24.
Installation and operation manual
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lrmeq4by1

Table of Contents