1. THE ELECTRICAL SAUNA STOVE PACKAGE INCLUDES:
- Sauna stove jacket
- Stone basket with control device
- Mounting plate + anchor screws
- Installation instructions
2. BEFORE INSTALLATION
Check the following:
- The sauna stove is the right size (kW) for the size of the sauna (cu m).
- Table 1 shows the volumes of the sauna for the different types of stoves.
- If the sauna has non-insulated surfaces, for instance brick, tile or glass, 1.5 cu m must
be added to the sauna volume for each square metre of wall on the basis of which the
effect needed for the sauna stove is defined according to Table 1.
The volume values of the sauna according to Table 1 must not be exceeded
or lowered.
- The minimum height of the sauna and the distances of the minimum protected areas
have been defined in Table 1.
- Make sure that there is a sufficiently steady mounting plate for the anchor screws.
A thin panel alone is not enough. Additional supporting rails behind the panel or
reinforcement boards on the top of the panel which are fastened to the wall support can
be a reinforcement.
- Sauna stoves NME-450 and 600 can also be installed in a wall recess where the
protected areas must be considered according to Figure 1.
- Stove NME-900 must allowed to be installed in the wall recess.
ONLY ONE ELECTRICAL STOVE MUST BE INSTALLED IN THE SAUNA.
Scale 1. Installation data for the sauna stove NME
Stove modell
Effect
Steam room
Volyme
min
m 3
kW
NME 450
4,5
4
NME 600
6
6
NME 900
9
9
Minimum protection distances to the stove
Height
Sides
In front
max
min
A **)
B **)
m 3
cm
cm
cm
7
190
5
5
9
190
5
8
15
190
10
10
**) See Figure 1
In front
Ceiling
Floor
C **)
D **)
E **)
cm
cm
cm
2
115
12
2
115
12
2
115
12
*) The rubber cable H07RN-F or similar as a connection able
Stone amount
Connection*)
400V 3N
mm 2
kg
30
5x1,5
30
5x1,5
30
5x2,5
Fuses
A
3x10
3x10
3x16

Advertisement

loading

Summary of Contents for NARVI NME 450

  • Page 1 INSTALLATION MANUAL ELECTRICAL SAUNA STOVES - NME 450, NME 600, NME 900 1. THE ELECTRICAL SAUNA STOVE PACKAGE INCLUDES: - Sauna stove jacket - Stone basket with control device - Mounting plate + anchor screws - Installation instructions 2. BEFORE INSTALLATION Check the following: - The sauna stove is the right size (kW) for the size of the sauna (cu m).
  • Page 2 TYYPPI X min. mm NME 450 NME 600 NME 900 min. 20 cm Installation of stove in a wall recess. Kiukaan asennus seinäsyvennykseen NME 900 stoves are not allowed to Huom! NM 800 ja NM 900 kiuasta install into wall reces.
  • Page 3 Stage 3: TO PILE THE STONES - The stones are piled on the top of the fire grate in the stone capacity, in between the heating elements (resistors) so that the stones support each other. Please make sure that the resistors are not supporting the weight of the stones.
  • Page 4 6. SAFETY RAIL Min. 2 cm If needed, a safety rail can be built round the Min. 2 cm sauna stove (Figure 9). We recommend wood for this, in this case, the minimum distances stated for flamable constructions must absolutely Min.

This manual is also suitable for:

Nme 600Nme 900