    Testo for disposal. Specifications 2.1. The testo 184 data loggers are used to save and read out individual readings and measurement series. They have been specifically designed for monitoring the transportation of products subject to cold chain requirements.
  • Page 4: Technical Data

    PDF files, no software needs to be installed. Product versions T1 and T2 are single-use data loggers with a time-limited service life. 2.2. Technical data testo 184 T1, T2, T3, T4 Feature Values Display T1, T4: no T2, T3: yes...
  • Page 5 T1, T2: 12-month warranty from the production date, guarantee production date: see circled date code (MMDD) on the identification plate. T3, T4: 24-month warranty, warranty terms: see website www.testo.com/warranty testo 184 H1, G1 Feature Values Display Probe type H1: internal digital humidity sensor...
  • Page 6 For continuous application in high humidity (> 80 % RH at ≤ 30 °C for > 12 h, > 60 % RH at > 30 °C for > 12 h), please contact us via www.testo.com/service- contact DataLoggerStore 1.888.610.766 www.
  • Page 7: Product Description

    3 Product description Feature Values 24 months, warranty conditions: see website Warranty www.testo.com/warranty Product description 3.1. Status LEDs To increase the battery life, the status LEDs are not permanently illuminated. They flash once every 5 seconds. In hibernation mode, the status LEDs are disabled.
  • Page 8: Display (Lcd)

    3 Product description 3.2. Display (LCD) Not available for all product versions. 1 Measurement program running 2 Measurement program finished 3 Wait for start of measurement program 4 Highest saved reading 5 Lowest saved reading 6 Reading 7 Status information: start criterion Date/time programmed/time mark, measurement axes for acceleration measurement,...
  • Page 9: Key Functions

    3 Product description 3.3. Key functions Commissioning The data loggers are delivered in hibernation mode to prolong the battery life. In this mode, the status LEDs and the display are disabled. > Press the START key or the STOP key. Wait mode is activated.
  • Page 10 3 Product description Display T2 T3 H1 G1 Maximum acceleration reading, Y axis (Max, y, g) Maximum acceleration reading, Z axis (Max, z, g) Time mark ( ) Battery life in days ( STOP key ✓ mode and stop criterion Button Stop programmed. >...
  • Page 11 3 Product description A maximum of 10 time marks can be set. Setting a time mark resets the statistical values Min, and MKT. • Acceleration (shock): the (positive and negative) acceleration is measured in 3 measurement axes. Only those readings that exceed the set limit value (maximum value per 1 second) are stored and displayed.
  • Page 12: Using The Product

    The XML file can be used as a template for other data loggers (via copy/paste in the file explorer). 7. Close file. A message Do you want to save the changes to “testo 184 configuration.pdf” before closing? may appear. Answer this question with No.
  • Page 13 Alternatively, the data logger can also be configured using testo Comfort Software Professional (version 4.3 service pack 2 or later) or testo Comfort Software CFR (version 4.3 service pack 2 or later). Please consult the relevant software instruction manual. 4.2.
  • Page 14: Reading Out Data

    To carry out detailed analysis or to further process readings, the software testo Comfort Software Professional (version 4.3 service pack 2 or later) or testo Comfort Software CFR (version 4.3 service pack 2 of later) is required (accessory). Please consult the relevant software instruction manual.
  • Page 15: Maintaining The Product

    5 Maintaining the product • To transfer data, the data logger must be placed on the NFC transmitter of the target device. • Please also consult the instruction manual for the target device. Maintaining the product 5.1. Changing the batteries It is not possible to change the batteries for instrument types T1 and T2 (single-use data loggers).
  • Page 16: Tips And Assistance

    Configuration not possible, e.g. because mode is active. (instruments with display) If you have any questions please contact your local dealer or the Testo Customer Service. Contact details can be found on the internet: www.testo.com/service-contact DataLoggerStore 1.888.610.766 www. .com...