Water inlet fault
Problem
All TimeControl in-
operation indicators are
flashing quickly.
The warning buzzer is
sounding.
One of the following
faults appears in the
display:
Water inlet fault. Please
open the stopcock
Water inlet fault
The following message
appears in the display
during the
SolarSave
programme:
Water in. temp. too low
Possible cause and remedy
The tap is turned off.
Turn on the tap fully.
Before rectifying the problem, you must:
Switch the dishwasher off using the sensor.
Water intake is restricted.
Turn on the tap fully and start the programme
again.
Clean the water inlet filter (see "Maintenance").
The water pressure at the intake is lower than 50
kPa (0.5 bar).
Seek professional advice.
The intake water has not reached the required
temperature of 45°C (see "Water connection -
Connection to the water supply").
Start the programme again.
If the fault message appears again, select a
different programme.
Problem solving guide