Water inlet fault

Problem
All TimeControl in-
operation indicators are
flashing quickly.
The warning buzzer is
sounding.
One of the following
faults appears in the
display:
 
Water inlet fault. Please
open the stopcock
 
Water inlet fault
The following message
appears in the display
during the
SolarSave
programme:
Water in. temp. too low
Possible cause and remedy
The tap is turned off.
 Turn on the tap fully.
Before rectifying the problem, you must:
 Switch the dishwasher off using the  sensor.
Water intake is restricted.
 Turn on the tap fully and start the programme
again.
 Clean the water inlet filter (see "Maintenance").
 The water pressure at the intake is lower than 50
kPa (0.5 bar).
Seek professional advice.
The intake water has not reached the required
temperature of 45°C (see "Water connection -
Connection to the water supply").
 Start the programme again.
 If the fault message appears again, select a
different programme.