Mitsubishi Electric JT-SB216JSH2-W-NE Handbook page 13

Hand dryer
Hide thumbs Also See for JT-SB216JSH2-W-NE:
Table of Contents

Advertisement

(2) Troubleshooting
Description of the error mode display
<JT-SB216JSH2-W/H/S-NE>
Power lamp
Heater lamp
: ON
: Slow blinking (ON for 0.4 seconds/ OFF for 0.4 seconds)
: OFF
: Fast blinking (ON for 0.1 second/ OFF for 0.1 second)
Troubles with error display
Error Mode Display
Power
Heater/Check
(Lamps do not light.)
<JT-SB216KSN2-W-NE>
Power lamp
Check lamp
Checkpoint
Power supply
Check that approx. 220 to 240 V AC is supplied at both ends of the
voltage
power cord connections on the terminal block.
■ If 220 to 240 V AC is not supplied, check the following points.
1 Check that the earth leakage breaker is turned ON.
2 Check that the power cord is connected securely to the terminal
block.
Power supply
Check that approx. 220 to 240 V AC is supplied between TAB1 and
voltage on the
TAB2 (orange) on the power circuit board (JT-30P8H).
power circuit
board (JT-30P8H)
●If 220 to 240 V AC is not supplied, check the following points.
Power supply
Check that approx. 220 to 240 V AC is supplied to the following
voltage on the
points in the order of 1 and 2.
filter circuit board
1 Between TAB20 and TAB21 (red)
If approx. 220 to 240 V AC is not supplied, check the power
(JT-30F8)
supply voltage of the earth leakage breaker.
2 Between TAB22 and TAB23 (orange)
If approx. 220 to 240 V AC is not supplied, replace the filter
circuit board (JT-30F8).
●When 220 to 240 V AC is supplied, check the following points.
Connector dis-
Check if the connector CN19 on the display circuit board (JT-
connection for
30S5R) or CN18 on the control circuit board (JT-30M8A/JT-30M8/
the display circuit
JT-30M9A) is disconnected.
board (JT-30S5)
Connector discon-
Check if the connector CN2 on the power circuit board (JT-30P8H)
nection between
or CN5 on the control circuit board (JT-30M8A/JT-30M8/JT-30M9A)
the circuit boards
is disconnected.
Malfunction of the
If no error is found after checking the above, replace the control
control circuit board
circuit board (JT-30M8A/JT-30M8/JT-30M9A).
(JT-30M8A/JT-
30M8/JT-30M9A)
Malfunction of
If the hand dryer does not operate even after replacing the control
the power circuit
circuit board (JT-30M8A/JT-30M8/JT-30M9A), replace the power
board (JT-30P8H)
circuit board (JT-30P8H).
Check Method and Remedy