IC Live Users Manual - Models ICL-R & IC215S-R
SERVICING and TROUBLE SHOOTING (Continued)
3. Check for split pairs. A split pair cable will drop packets even if the cable is only 2 meters long. The incorrect wiring example
shown below represents a split pair.
4.
5.
Symptom: I can communicate with my Iconyx array, but I get errors when writing beams.
1.
count for all devices. Any device that shows errors has a suspect network connection. Review the previous page for
troubleshooting tips..
Symptom: Analog audio sounds like its gating.
1. You are sending a signal to Analog 1, but some other input is selected on the Connect tab. As an aid to troubleshooting the
Analog 1 input will always pass audio, but if some other input is selected, Analog 2 for example, the signal to Analog 1 must
1. You have the Ethernet cable plugged into a slave unit. Either move the cable to the master unit or set the unit with the cable to
be the master.
Symptom: My IC-Live Dual shows up as only a single IC Live module.
1.
master module or reset the DIP switches.
2.
3.
60
CORRECT WIRING
INCORRECT WIRING (Split Pair)