Ic live
Table of Contents

Advertisement

IC Live Users Manual - Models ICL-R & IC215S-R
Beam Angle aims the vertical beam up or
down. Try it out by selecting Beam Angle
you will need to press Enter to initiate the
change. You will also need to do a new
Calculate Mapping to view the change. The
old map will have been wiped out by the
program as you made the change.
beam's focal point in Height from Floor and
Distance from Front. Another way to position
the beam's focal point is to use the mouse
cursor to grab the end point of the aiming
axis and move it to the desired location. Try
graphs will change as the setup parameters
change.
program to map the array's performance on the audience area.
As soon as you press Calculate Mapping, a pop up screen will ask you to
choose the resolution of the simulation. Low Resolution simulations are much
faster to run than High Resolution ones. All you need to do to start the simula-
tion is to make your resolution choice by pressing one of the bars.
You also have the opportunity to choose the simulations Bandwidth, its Center
Frequency and its Weighting. The Frequency section lets you select center
frequencies from 100 to 10,000 Hz. The default selections for the Bandwidth
section allows you to run the simulation over 1 octave or 3 octave bands or
Broadband.
-
3150 Hz" would run the simulation over the frequency range of 1000 too 3150
Hz.
We'll choose the default settings for this exercise, but you may want to try out
all the different settings to become familiar with them and the performance of
steerable arrays.