Quidway S5012G-DC Installation Manual page 5

S5000 series ethernet switches
Table of Contents

Advertisement

Installation Manual
Quidway S5000 Series Ethernet Switches
System status indicators
MODE
Port status
mode indicators
Figure 1-1 S5012G front panel
II. Indicators on front panel
The indicator meaning on the front panel of S5012G is listed in the table below.
Table 1-1 System status indicators of S5012G switch
Description
System
status
indicators
12 GE interfaces
Indicator
Status
ON or
blinking
RUN
OFF
ON
MPS(Mai
n Power
Supply)
OFF
ON
RPS(Red
undant
Power
System)
Blinkin
g
OFF
Huawei Technologies Proprietary
1-3
Chapter 1 Product Overview
4 GBIC interfaces
Status Description
Blinking with frequency 0.5Hz means the
switch is running normally.
Blinking with frequency 4Hz means the
switch is downloading host program.
Steady ON means the switch is powered on
but not loading application program yet or the
switch is in fault state.
The switch is powered off or in fault state.
The master power module of the switch
works normally.
The master power module of the switch is
disconnected or in fault state.
The redundant power module of the switch is
in service and in normal status.
(If MPS is on, the switch is powered by
master power module, no matter what status
RPS is in.
When MPS is off but RPS is on, the switch is
powered by redundant power module.)
Blinking with frequency 4Hz means the
redundant power module is in fault state.
The redundant power module of the switch is
idle or disconnected.
Console port