has any faults, there will not be any screen display at the configuration terminal or the
displayed characters will be totally illegible.
I. Troubleshooting when there is no terminal display
If there is no output information after the configuration is powered on, please check
whether
The power supply is normal
The Console cable is connected correctly
If no problems are found after the above-mentioned items have been checked, the
cause may lie in the Console cable or the settings of the terminal (such as
HyperTerminal) parameters. Please perform the corresponding check.
II. Troubleshooting when the terminal display is illegible
If there is illegible display at the configuration terminal, the cause might lie in the
parameter setting error at the terminal (such as HyperTerminal). Please confirm the
terminal parameter (such as HyperTerminal) settings: baud rate should be set to 9600,
data bit to 8, parity to none, stop bit to 1 and flow control to none, and select VT100 as
terminal emulation.
Huawei Technologies Proprietary
6-2
Chapter 6 Maintenance and Troubleshooting