Cisco Nexus 6000 Series Configuration Manual page 74

Hide thumbs Also See for Nexus 6000 Series:
Table of Contents

Advertisement

Configuration Examples for FCoE NPV
Interface: vfc120, State: Down
Interface: vfc130, State: Trunking
Number of External Interfaces: 8
Server Interfaces:
==================
Interface:
Interface:
Interface:
Interface: vfc5000, VSAN: 4094, State: Down
Interface: vfc6000, VSAN: 4094, State: Down
Interface: vfc7000, VSAN: 4094, State: Down
Interface: vfc8090, VSAN: 4094, State: Down
Interface: vfc8191, VSAN: 4094, State: Down
Number of Server Interfaces: 8
This example shows the running configuration of port channel 130:
switch# show running-config interface port-channel 130
!Command: show running-config interface port-channel130
!Time: Wed Jan
version 6.0(2)N1(1)
interface port-channel130
switchport mode trunk
switchport trunk native vlan 2
no negotiate auto
This example shows the impact of FCoE NPV on an ISSU:
switch# show fcoe-npv issu-impact
show fcoe-npv issu-impact
-------------------------
Please make sure to enable "disable-fka" on all logged in VFCs
Please increase the FKA duration to 60 seconds on FCF
Active VNP ports with no disable-fka set
----------------------------------------
vfc90
vfc100
vfc110
vfc111
vfc120
vfc130
ISSU downgrade not supported as feature fcoe-npv is enabled
switch#
Cisco Nexus 6000 Series NX-OS SAN Switching Configuration Guide, Release 6.x
54
VSAN:
1, State: Waiting For VSAN Up
VSAN:
200, State: Up
VSAN:
400, State: Up
VSAN:
100, State: Up
VSAN:
300, State: Up
VSAN:
500, State: Up, FCID: 0xa10002
vfc1, VSAN:
20, State: Up
vfc2, VSAN: 4094, State: Down
vfc3, VSAN: 4094, State: Down
30 22:01:05 2013
Configuring FCoE NPV
OL-27932-01

Advertisement

Table of Contents
loading