NOTE: If the command runs successfully, the message OK appears.
d.
Configure the Network Control Mode with the at#ncm command.
Example: at#ncm=1,3.
e.
Activate the Packet Data Protocol with the at+cgact command.
Example: at+cgact=1,3.
f.
To view the PDP Context Read Dynamic Parameters, that is, bearer_id, apn, ip_addr, subnet_mask, gw_addr,
DNS_prim_addr, DNS_sec_addr, P-CSCF_prim_addr, and P-CSCF_sec_addr parameters, run the at
+cgcontrdp command.
Example: at+cgcontrdp=3
+CGCONTRDP:
,7,"broadband.mnc480.mcc311.gprs","100.106.47.7.255.0.0.0","100.1
6.47.8","198.224.157.135","0.0.0.0","0.0.0.0","0.0.00"
g.
Exit the Minicom module.
h.
In the Linux terminal configure the connection with the following commands
root@WR-IntelligentDevice:~# ifconfig wwan0 ip_addr netmask subnet_mask
up
root@WR-IntelligentDevice:~# route add default gw gw_addr wwan0
root@WR-IntelligentDevice:~# echo nameserver DNS_prim_addr >>/etc/
resolv.conf
Example:
root@WR-IntelligentDevice:~# ifconfig wwan0 100.106.47.7 netmask
255.0.0.0 up
root@WR-IntelligentDevice:~# route add default gw 100.106.47.8 wwan0
root@WR-IntelligentDevice:~# echo nameserver 198.224.157.135 >>/etc/
resolv.conf
i.
Log in to the Minicom module using the minicom -D /dev/ttyACM0 command.
j.
Connect to the mobile network using the at+cgdata command.
Example:at+cgdata="M-RAW_IP",3
To disconnect from the mobile network
a.
Open the Minicom terminal.
b.
Enter the at+cgdata="M-RAW_IP",3 command.
c.
Close the Minicom terminal.
d.
Enter the root@WR-IntelligentDevice:~# ifconfig wwan0 down command.

Mounting your Edge Gateway

Mounting the Edge Gateway using the standard-mount bracket

NOTE: The mounting brackets are shipped with only those screws that are required for securing the mounting
brackets to the Edge Gateway.
1.
Secure the standard-mount bracket to the back of the Edge Gateway by using the four M4x4.5 screws.
NOTE: Torque the screws at 8+/-0.5 kilograms-centimeter (17.64+/-1.1 pounds-inch).
19