6.4.1 Condense drain connections
Condensate that forms during the operation of the heat
pump flows through an appropriate discharge pipe
(G 1/2") that passes inside cladding and it comes out on
the side of the equipment.
This must be connected to a duct via a siphon so that
the condensate can flow freely (Fig. 9a or Fig. 9b).
Ø20
≥ 60
Fig. 9a – Examples of condensate drain connection via
siphon
G ½"
≥ 60
Fig. 9b – Example of condensate drain connection via
siphon with water shut-off valve
Installation and user manual
Solar power system
6.5
integration
The following illustration (Fig. 10) shows an example of
solar power system integration.
alv
ola
Cold w ater intake pipe
Solar pow er system pump and accessories
Solar collectors
Heat pump
Recirculation pump
Spring check valve
Drain tap
Solar thermal pow er coil
Hot w ater outlet pipe
Fig. 10 – Example of solar power system integration