6.4.1 Condense drain connections

Condensate that forms during the operation of the heat
pump flows through an appropriate discharge pipe
(G 1/2") that passes inside cladding and it comes out on
the side of the equipment.
This must be connected to a duct via a siphon so that
the condensate can flow freely (Fig. 9a or Fig. 9b).
Ø20
≥ 60
Fig. 9a – Examples of condensate drain connection via
siphon
G ½"
≥ 60
Fig. 9b – Example of condensate drain connection via
siphon with water shut-off valve
Installation and user manual
Solar power system
6.5
integration
The following illustration (Fig. 10) shows an example of

solar power system integration.

alv
ola
 Cold w ater intake pipe
 Solar pow er system pump and accessories
 Solar collectors
 Heat pump
 Recirculation pump
 Spring check valve
 Drain tap
 Solar thermal pow er coil
 Hot w ater outlet pipe
Fig. 10 – Example of solar power system integration