Specifications
Computer dimensions
Width
Depth
Height
Weight
Temperature Range
Operating
Nonoperating
NOTE:
The operating temperature is derated 1.0° C per 300 m (1000 ft) when used above 1524m (5000 ft) above sea level; no direct
sustained sunlight. Maximum rate of change is 10° C/hr. The upper limit may be limited by the type and number of options installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
Maximum Altitude (unpressurized)
Operating (with solid-state drives)
Operating (with hard drives)
Nonoperating
Power Supply 1
Operating voltage range
Rated voltage frequency range
Operating line frequency range
Standard Efficiency
High Efficiency
Rated Input Current
Power Supply 2
Metric
21.6 cm
55.1 cm
44.5 cm
31.7kg maximum, 22.4 kg
minimum, 23.7 kg typical (exact
weights depend on
configuration)
5° to 35°C
-40° to 60°C
10-90%
5-95%
5,000 m
3,048 m
15,240 m
1125W / 1275W* / 1450W*
90-269 VAC
100-127 VAC @ 50-60 Hz, 200-240 VAC @ 50-60 Hz, 118 VAC @
400 Hz
100-127 VAC @ 47-66 Hz, 200-240 VAC @ 47-66 Hz, 118 VAC @
393-407 Hz
12A @ 100-127 VAC, 10A @ 200-240 VAC, 12A @ 118 VAC
180 W, 250 W active PFC
1000 W 90% efficiency, custom power supply (wide-ranging, active
PFC)
1000 W
12A @ 100-127 VAC, 6.3A @ 200-240 VAC
12A @ 118 VAC
1450W / 1550W* / 1700W*
U.S.
8.5 in
21.7 in
17.5 in
70.0 lbs maximum, 49.4 lbs
minimum, 52.2 lbs typical (exact
weights depend on
configuration)
40° to 95°F
-40° to 140°F
10-90%
5-95%
16,404 ft
10,000 ft
50,000 ft
103