Page 1
VR CLR LOCK C.TEMP CONT KNEE GAIN PED FLARE MASTER FLARE BLACK AUTO TALLY LENS EXT KNOB FREE MON SEL OPEN IRIS FULL ±1 ±2 RANGE SENS IRIS CABLE OPEN SHORT ALARM CALL -100 OCP-100 OPERATION CONTROL PANEL OPERATION MANUAL...
KNEE GAIN PED FLARE MASTER FLARE BLACK AUTO TALLY LENS EXT KNOB FREE MON SEL OPEN IRIS FULL ±1 ±2 RANGE SENS IRIS CABLE OPEN SHORT ALARM CALL -100 OCP-100 OPERATION CONTROL PANEL OPERATION MANUAL 1209 1nd Edition (U) (E)
(once every 3 years or 8000 hours use) is recommended to extend the life and safe use of this product for a long time. Please contact Ikegami's sales and service centers or Techno Ikegami Co., Ltd. for the regular maintenance and repair of our products.
HOW TO USE OPERATION MANUAL The OCP-100 OPERATION CONTROL PANEL OPERATION MANUAL is intended to describe how to operate the OCP-100. This manual is written for readers with a basic knowledge of handling broadcast cameras and Base Station (BS), so technical terms are not explained here.
Page 10
When the PM IND/PAGE switch is held for more than 1 second, the mode is changed to menu remote mode, and the menu of the camera or BS can be controlled from the OCP. Refer to “3.5 Menu Remote” for details. OCP-100 OCP-100 1209 VOL1 (U) (E)
Page 11
: -11, -9, -7, -5, -3 The LED indicates the current setting. When LEDs for ±11 and ±7 light simultaneously, it indicates ±9. Similarly, when LEDs for ±7 and ±3 light simultaneously, it indicates ±5. OCP-100 1209 VOL1 (U) (E) OCP-100...
Page 12
This is a switch for setting the Analog G GAIN control to master gain or to G gain. By setting the switch to “ON”, the master gain is selected, or by setting it to “OFF”, the G gain is selected. - AUTO KNEE switch Used to set the AUTO KNEE mode. OCP-100 OCP-100 1209 VOL1 (U) (E)
Page 13
Used to set the AUTO IRIS mode. 15 JOYSTICK - IRIS control and M-PED control Controls the IRIS of the lens and the master pedestal. In AUTO IRIS mode, the iris is controlled with ±1 stop range. OCP-100 1209 VOL1 (U) (E) OCP-100...
Page 14
When the optical level of the Camera Head and CCU is normal, the GREEN lamp is turned on; at an attenuated level the ORANGE lamp and at an insuffi cient level the RED lamp is turned on. OCP-100 OCP-100 1209 VOL1 (U) (E)
Page 15
Connect the COLOR LINK cable. Bridge-connecting multiple OCPs with the COLOR LINK cables enables color link operation. 29 COMMAND connector Connect the CP cable. 30 PREVIEW connector Output connector for the PREVIEW switch (see item 15). OCP-100 1209 VOL1 (U) (E) OCP-100...
Page 16
1. NAME and FUNCTION OCP-100 OCP-100 1209 VOL1 (U) (E)
■ ■ Connecting OCP and BS Connecting OCP and BS Connect the COMM connector of the OCP to the OCP/CCP connector of the BS using a CP cable. OCP/CCP connector COMM connector Rear view of the BS OCP-100 1209 VOL1 (U) (E) OCP-100...
Page 18
Connect the COLOR LINK connector of the OCP with the COLOR LINK cable by bridge connection. As the COLOR LINK connector IN and OUT cannot be differentiated, the connecting position is free. COLOR LINK connector OCP-1 OCP-2 OCP-3 COLOR LINK cable (maximum length 10m) OCP-100 OCP-100 1209 VOL1 (U) (E)
HET TRX (+) Color link control signal output (+) HET TRX (-) Color link control signal output (-) HET GND Ground for Color link control signal _ N. C (spare) _ N. C (spare) OCP-100 1209 VOL1 (U) (E) OCP-100...
Page 20
DC + 12 V power supply from BS + 12 V RET Ground for DC + 12 V power supply INCOM TALK INCOM microphone signal to BS INCOM RECEIVE INCOM receiver signal from BS OCP-100 OCP-100 1209 VOL1 (U) (E)
MASTER FLARE BLACK AUTO TALLY LENS EXT KNOB FREE MON SEL OPEN IRIS FULL ±1 ±2 RANGE SENS IRIS CABLE BS MAIN POWER switch OPEN SHORT ALARM CALL -100 Front View of the BS OCP-100 1209 VOL1 (U) (E) OCP-100...
GAIN PED FLARE MASTER FLARE BLACK AUTO TALLY MONITOR SELECT switch LENS EXT “ENC” KNOB FREE MON SEL OPEN IRIS FULL ±1 ±2 RANGE SENS IRIS CABLE OPEN SHORT ALARM CALL 100% -100 -20% OCP-100 OCP-100 1209 VOL1 (U) (E)
IRIS FULL ±1 ±2 RANGE SENS IRIS CABLE OPEN SHORT ALARM CALL -100 3.2.3 Checking Images on Charts 3.2.3 Checking Images on Charts Shoot an external chart and check that the image is normal. OCP-100 1209 VOL1 (U) (E) OCP-100...
Used to adjust the R, G, B black balance. Perform as required during operation. Auto setup is converged to the reference fi le values. At shipment, this reference fi le values are created in the memory. To change the reference fi le values, refer to the MCP operation instruction. OCP-100 OCP-100 1209 VOL1 (U) (E)
It is recommended to center the VR controls for gray scale adjustment prior to running Quick Auto Setup to avoid one sided VR control range. DTL and Color SAT are not adjusted by the Quick Auto Setup, so VRs should be centered using the knob free function. OCP-100 1209 VOL1 (U) (E) OCP-100...
Note: Depending on the CAMERA models, the area where White Balance is adjusted will be displayed in a Zebra Pattern when “AWB OK” is selected (that is, when the automatic white balance is enabled). OCP-100 OCP-100 1209 VOL1 (U) (E)
To execute ABS, press the QUICK switch and then the ABB switch. AUTO BLACK SHADING will be executed. PED, BLACK SET and BLACK SHADING are executed for the AUTO BLACK SHADING. (PED and BLACK SET are also executed when auto black balance is executed.) OCP-100 1209 VOL1 (U) (E) OCP-100...
- After the Master has been selected, no Slave can be added. - By turning off the COLOR LINK switch of a Slave, the COLOR LINK operation of that particular Panel can be disabled. OCP-100 OCP-100 1209 VOL1 (U) (E)
Page 29
- On the basis of the Analog data sent from the Master, the Slave will calculate the data to be sent to the Camera Head and will send - The ON/OFF items will be sent to the Camera Head without change. OCP-100 1209 VOL1 (U) (E) OCP-100...
Page 30
The name of a function will appear on the Display at the center. By operating the UP/DOWN switch, the function indicated on the screen will be altered. When the UP/DOWN switch is operated, the displayed function will be registered. To exit from the ”REGISTRATION” mode, press down the F1 or the F2 switch. OCP-100 OCP-100 1209 VOL1 (U) (E)
OFF when the TALLY is ON. Note: Depending on the BS model, some cable extension adaptor is not displayed on the menu unless the BARS switch is set to ON. Refer to the manuals for each BS model. OCP-100 OCP-100 1209 VOL1 (U) (E)
- When RAM clearing is completed, “COMP” “LETE” “!!!!” will be displayed, indicating that the Initialization has been completed. - After 1 second since the completion of the Initialization, the display will be changed to “OCP” “REST” “ART !”. Then, 2 seconds later, the Panel will automatically restart. OCP-100 1209 VOL1 (U) (E) OCP-100...
Page 34
*3 : Master if the Master exists, or G ch if not. *4 : Change the items uncontrollable by OCP-100 to the controllable items by selecting the standard setting according to the operating conditions as shown on the next page (the Auto STD Items). (This operation is not effective when the parallel connection is employed.)
Page 35
*2 : At CALL OFF and the scene fi le OFF *3 : When the ON/OFF control is not registered on the F KEY *4 : When the ON/OFF control is not registered but the Analog control is registered on the F KEY OCP-100 1209 VOL1 (U) (E) OCP-100...
Even if the indicator is not fl ashing, setting the PM IND/PAGE switch on the OCP to “ON” will display the self-diagnosis information on the PM in the same way (Page 1-2: see item 7). OCP-100 1209 VOL1 (U) (E) OCP-100...
19.6133 m / S2 (2G) The test is conducted once for each of X, Y, and Z axes with 1 octave (i.e., 57 to 150 Hz) in 1 minute. (4) EMI FCC class A OCP-100 1209 VOL1 (U) (E) OCP-100...
Page 43
Ikegami Tsushinki Co., Ltd. - All rights reserved. Reproduction or duplication, without permission of Ikegami Tsushinki Co., Ltd. of editorial or pictorial content in whole or in part, in any manner, is prohibited. - Specifi cations and design are subject to change without prior notice.
Need help?
Do you have a question about the OCP-100 and is the answer not in the manual?