3.15 MONITOR/REMOTE
3.15.1 Preparation
Connect the inspection circuit to the MONITOR/REMOTE terminal (JK304).
Check that the tolerance of the connected resistor is 1% or less, the rated power is 1/4 W or more and the tolerance of the DC
current voltage is 1% or less.
3.15.2 Output level
Input a 1 kHz, -10 dBu signal and check that the output voltage at pins 14 and 15 of JK304 is 4.8 ± 1.0 dBu.
3.15.3 Mute and protection status
Input a 1 kHz, -10 dBu signal.
Check that the DC voltage at pins 10 and 11 of JK304 is +2 ± 0.5V .
Turn on SW1 and check that the DC voltage at pin 11 of JK304 is 0.5 V or less and the voltage level at the output terminal of
the A channel is -30 dBu or lower.
Turn on SW2 and check that the DC voltage at pin 10 of JK304 is 0.5 V or less and the voltage level at the output terminal of
the B channels is -30 dBu or lower.
3.15.4 Model ID
Turn on SW3 and check that the DC output voltage at pin 3 of JK951 is within the range for "ID-V" specified in the table below.
XP7000
ID-V
2.00
+/- 0.06 V
3.15.5 Standby
Turn on SW4 and check that the POWER LED lights up in orange and the primary power is 5W or less.
7.5 k-ohms
7.5 k-ohms
180 ohms
180 ohms
SW1
SW2
1.5 k-ohms
5 V
SW3
330 ohms
SW4
XP5000
2.22
+/- 0.06 V
15 pin
14 pin
13 pin
12 pin
11 pin
10 pin
9 pin
8 pin
7 pin
6 pin
5 pin
4 pin
3 pin
2 pin
1 pin
XP7000/XP5000
39

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Xp-5000