Error messages (LED indicator) - PRIME™ tools
In case of any error, the error code will flash on the PRIME™ tool according to the table.
Measures for acknowledging fault messages:
Activate the trigger on the connected tool. No further action is required if the flashing stops.
If the fault persists, follow the instructions given in the troubleshooting guide or get in touch with an authorized dealer.
The power unit software can be updated. Contact your service agent for further information.
1
Red
2
Yellow
3
Green
4
Green
5
Green
Solid light
Flashing light
1
2
3
4
5
F0101
FXX08*
Fault Code
Error messages
F0101
Over current detected
High motor temperature
FXX08*
detected
Low input voltage
F0112
detected
High input voltage
F0113
detected
Tool temperature sensor
FXX14*
error detected
Fault detected in
F0118
hardware
Temperature in the PP
F0119
too high
F0130
Generic error
* XX different numbers depending on the tool that is connected to the power unit.
20 – English
MAINTENANCE
F0112
F0113
Cause
Active tool current too
high
Tool motor temperature is
too high
Input voltage too low
Input voltage too high
Interruption or short
circuit in the temperature
sensor.
Hardware fault
Power pack overheated
Jammed blade
FXX14*
F0118
Steps
Contact your service workshop if the
problem remains.
Increase the flow of water coolant. Ensure
clean water is used so as not to clog up the
water channels. See Technical data for
specifications for water flow, temperature
and pressure.
Check minimum input power in manual
Check maximum input power in manual
Contact your service agent.
Contact your service workshop if the
problem remains.
Increase the flow of water coolant. Ensure
clean water is used so as not to clog up the
water channels. See Technical data for
specifications for water flow, temperature
and pressure.
F0119
F0130