SCE 1000 Operational Status

The following table lists the operational states of the SCE 1000. The Status LED on the SCE 1000 Front Panel reflects the current
SCE 1000 operational status. The operational status can be displayed using CLI command show system operation-status.
Table 4
SCE 1000 Operational States
SCE 1000 Operational Status
Booting
Operational
Warning
Failure
Description
Initial state after reset
SCE 1000 becomes operational after
completing the following process:
Boot is completed
Power self-tests are completed without
failure
Platform configuration is applied
SCE 1000 is fully operational (as above)
but one of the following occurred:
Line ports (GBE ports) to the link are
down
Management port link is down
Temperature raised above threshold
Voltage not in required range
Fans problem
Power supply problem
Insufficient space on the disk
If the condition that caused the SCE
1000 to be in Warning state is resolved
(for example, link is up) the SCE 1000
reverts to Operational state.
System is in Failure state after Boot due
to one of the following conditions:
Power on test failure
Three abnormal reboots in less than 20
minutes
Platform configured to enter Failure
mode consequent to failure-induced
reboot (this is configurable using CLI
command)
Depending on the cause of failure, the
management interface and the platform
configuration may or may not be
active/available.