Omron NX-EIC202 User Manual page 378

Machine automation controller nx-series ethernet/ip coupler unit
Hide thumbs Also See for NX-EIC202:
Table of Contents

Advertisement

Appendices
General status
code (hex)
27
28
29
2A
2B-CF
D0-FF
Example of Additional Status in Case That General Status is 01 Hex
(Status of Connection Manager Object)
General status
code (hex)
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
A - 32
Status name
Unexpected attribute in list
Invalid Member ID
Member not settable
Group 2 only server general failure
---
Reserved for Object Class and service
errors
Additional status code (hex)
0100
0103
0106
0107
0108
0109
0110
0111
0113
0114
0115
0116
0117
0118
0119
011A
011B
0203
Description
An attempt was made to set an attribute that is not
able to be set at this time.
The Member ID specified in the request does not
exist in the specified Class/Instance/Attribute.
A request to modify a non-modifiable member was
received.
This error code may only be reported by DeviceNet
group 2 only servers with 4K or less code space
and only in place of Service not supported, Attri-
bute not supported and Attribute not settable.
Reserved by CIP for future extensions
This range of error codes is to be used to indicate
Object Class specific errors. Use of this range
should only be performed when none of the Error
Codes presented in this table accurately reflect the
error that was encountered.
Description
Connection in Use or Duplicate Forward Open.
Transport Class and Trigger combination not sup-
ported
Ownership Conflict
Connection not found at target application.
Invalid Connection Type. Indicates a problem with
either the Connection Type or Priority of the Con-
nection.
Invalid Connection Size
Device not configured
RPI not supported. May also indicate problem with
connection time-out multiplier, or production inhibit
time.
Connection Manager cannot support any more
connections
Either the Vendor Id or the Product Code in the key
segment did not match the device
Product Type in the key segment did not match the
device
Major or Minor Revision information in the key seg-
ment did not match the device
Invalid Connection Point
Invalid Configuration Format
Connection request fails since there is no con-
trolling connection currently open.
Target Application cannot support any more con-
nections
RPI is smaller than the Production Inhibit Time.
Connection cannot be closed since the connection
has timed out
NX-series EtherNet/IP Coupler Unit User's Manual (W536)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents