Trouble Codes
L8
01
No Full wave signal
02
Full wave signal error
20
MFP PWB communication trouble
PC
--
Personal counter not installed
U1
01
Battery trouble.
U2
00
MFP EEPROM read/write error
05
Erroneous detection of account
management data
11
MFP PWB EEPROM check sum error.
30
Serial number discrepancy (MFP – PCU)
40
SD card system storage data error
41
HDD system storage data area error
42
Machine adjustment data (system storage
area) error
50
HDD user authentication data check sum
error
60
Watermark check error.
80
SCU PWB EEPROM read/write error.
81
SCU PWB EEPROM check sum error.
90
PCU PWB EEPROM read/write error.
91
PCU PWB EEPROM check sum error
U5
00
DSPF feed unit communication trouble
16
DSPF feed unit fan trouble
30
DSPF tray lift up trouble
31
DSPF tray lift down trouble
U6
09
LCC lift motor trouble
20
LCC control PWB - PCU PWB
communication error
21
LCC transport motor trouble
22
LCC 24V power abnormality
23
A3 LCC tray descending trouble (Reverse
winding detection) (A3 LCC)
24
A3 LCC tray lock detection trouble
29
LCT1 lift trouble
33
LCT2 reverse winding detection trouble
54
U6
34
LCT2 lock detection trouble
39
LCT2 lift trouble
43
LCT3 reverse winding detection trouble
44
LCT3 lock detection trouble
49
LCT3 lift trouble
51
LCC - Main unit combination trouble
53
Communication trouble between LCT's
54
Option installation combination trouble
63
Manual feed tray descending trouble
68
Manual feed tray paper feed position
abnormality
69
Manual feed tray lift trouble
73
LCT4 reverse winding detection trouble
74
LCT4 lock detection trouble
79
LCT4 lift motor trouble
80
Relay unit transport motor trouble
81
Power unit cooling fan motor trouble (1
series)
82
EEPROM trouble (1 series)
83
Room temperature thermistor breakdown
(1 series)
84
Room humidity thermistor breakdown (1
series)
85
Transport motor 1 trouble (2 series)
86
24V power trouble (2 series)
87
Power unit cooling fan motor trouble (2
series)
88
EEPROM trouble (2 series)
89
Room temperature thermistor breakdown
(2 series)
90
Room humidity thermistor breakdown (2
series)
U7
50
Communication trouble between main
unit and vendor control
51
Vendor machine error
UC
02
IPD/DOCC - ASIC CPT function trouble
12
IPD/DOCC - ASIC CPT function trouble
(DSPF detection)
20
IPD/DOCC-ASIC DOCC function trouble
30
IPD/DOCC-ASIC DOCC function trouble
(DSPF detection)