TECHNICAL & WARRANTY INFORMATION
GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that
is microbiologically unsafe or unknown quality without adequate disinfection before and after the system. Systems certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
2. Operating Temperature:
3. Operating Water Pressure:
4. pH
5. Maximum Iron present in incoming water supply must be less than 0.2 ppm.
6. Hardness of more than 10 grains per gallon (170 ppm) may reduce RO membrane life expectancy.
7. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 58. This
system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) at concentrations of 0.30 mg/L or
less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free
chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined
chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic, Please see the Arsenic Facts section of the Performance Data
Sheet for further information.
Avg. In.
(mg/L)
Arsenic (Pentavalent)
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent)
Chromium (Trivalent)
Copper Reduction
Cysts
92,000#/ml
Fluoride Reduction
Lead Reduction
Perchlorate
Radium 226/228
25pCi/L
Selenium
TDS
Turbidity
Recovery - 22%
Depending on water chemistry, water temperature, and water pressure Premier's R.O. Systems production and performance will vary.
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under
operating conditions that approximate typical daily usage. Recovery rating means the percentage of the influent water to the membrane portion
of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the
storage tank is bypassed. There is an average of 4 gallons of reject water for every 1 gallon of product water produced.
REFER TO OWNER'S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY
INFORMATION.
Phone: (480) 675-7995
8716 W Ludlow Drive Suite #1
System conforms to NSF Standard 58 for specific claims.
Maximum: 100°F (40.5°C)
Maximum: 85 psi (6.0kg/cm2)
2 to 11
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description
Sediment Pre-filter:
Carbon Pre-filter:
VOC Carbon filter
50 GPD R.O. Membrane:
Avg. Eff.
% Reduction pH
(mg/L)
.310
0.001
9.2
0.08
0.031
0.0004
0.30
0.002
0.30
0.001
3.2
0.02
3 #/ml
99.99%
8.7
0.19
0.15
0.002
130
2.8
5pCi/L
94.85
<0.2
770
35
11.3
0.1
Fax: (623) 866-5666
Watts Premier
Peoria, AZ 85381
RO-Pure PLUS
#105311
#105351
#105381
#105331
Pressure
99.6%
7.24
50psi
99.0%
7.64
50psi
98.0%
7.49
50psi
99.0%
7.24
50psi
99.0%
7.64
50psi
99.0%
7.40
50psi
7.44
50psi
97.0%
7.24
50psi
98.8%
7.39
50psi
97.9%
80.0%
7.24
50psi
97.0%
7.24
50psi
95.0%
7.28
50psi
99.0%
7.43
50psi
Daily Production Rate - 20.5 GPD
Page 17
Minimum: 40° (4.4°)
Minimum: 40 psi (2.8kg/cm2)
Change time Frame
6 Months
6 Months
12 Months
2 to 5 years
Max Eff.
Inf. challenge
mg/L
concentration
mg/L
0.002
0.30±10%
0.12
10.0±10%
0.0008
0.03±10%
0.004
0.03±10%
0.002
0.03±10%
0.04
3.0±10%
18
minimum 50,000/mL
0.3
8.0±10%
0.005
0.15±10%
5pCi/L
25pCiL±10%
<0.2
0.10±10%
26.0
750±40mg/L
0-1
11±1mg/L
Efficiency - 10.5%
www.PremierH2o.com
Max Allowable
concentration
mg/L
0.010 mg/L
2.0
0005
0.1
0.1
1.3
N/A
1.5
0.0107
5pCiL
0.05
187
0.5NTU